8-35
January 24, 2017
Structure Function Principle
CLG835H
Monitoring system
XE7 Parking brake low pressure alarm
switch
Test on pressure switch failures
1. Unplug the connector connected to pressure
switch in the rear frame harness;
2. Remove the pressure switch from the com-
plete machine;
3. Assess the action value of pressure switch
with pressure test bed, and its contact type is
normally closed with action value up to
11Mpa.
Parking brake control pressure switch
Test on pressure switch failures
1. Unplug the connector connected to pressure
switch in the rear frame harness;
2. Remove the pressure switch from the com-
plete machine;
3. Assess the action value of pressure switch
with pressure test bed, and its contact type is
normally open with action value up to 7Mpa.
P18E00040
P18E00041