8-42
Structure Function Principle
January 24, 2017
Monitoring system
CLG835H
Circuit for voltage indication
For monitoring the machine system voltage, lights when the machine power voltage is lower than 24.8V,
extinguishes when within 24.8-29.5 V, lights when within 29.5-31.5 V, and blinks when greater than
31.5V.
The machine uses Perkins Electric Injection Engine whose ECM sends the voltage parameter of com-
plete machine to the meter by CAN bus after monitoring and reading. The meter judge the range of volt-
age by analysis of CAN agreement, eventually to control the ON/OFF of voltage indicator.