2-35
January 24, 2017
Structure Function Principle
CLG835H
DEF pipeline assembly
DEF pump
Part Structure and Principle Introduction
Urea pump will pump urea solution from urea tank, and the urea solution is transported to the nozzle of
diesel particle filter after filtering.
1. DCU
2. Mounting Tab
3. PEU Harness Connectror
4. Mounting Tab
5. DEF Outlet to injector
6. DEF inlet from Tank
7. Mounting Tab
8. Harness Restraint
9. Vent
10.Mounting Tab
11.Cap for serviceable filter on top of unit
P18P00044
DCU
Mounting
Tab
PEU Harness
Connectror
Mounting
Tab
DEF Outlet to injector
DEF inlet from Tank
Mounting Tab
Harness
Restraint
Vent
Mounting Tab
Cap for serviceable
filter on top of unit
DEF flows into DEF pump
DEF flows toward nozzle
1
2
3
4
10
9
8
7
6
5
11
Summary of Contents for CLG835H
Page 2: ......
Page 4: ...Contents January 24 2017 CLG835H...
Page 6: ...1 2 General Information January 24 2017 CLG835H...
Page 38: ...1 34 Machine Inspection Table January 24 2017 CLG835H...
Page 156: ...3 2 Power Train System January 24 2017 CLG835H...
Page 214: ...3 2 Power Train System January 24 2017 CLG835H...
Page 272: ...3 60 Testing and adjustment January 24 2017 Power Train Test CLG835H...
Page 276: ...4 4 Hydraulic System January 24 2017 CLG835H...
Page 552: ...6 2 Driver s Cab System January 24 2017 CLG835H...
Page 608: ...7 2 Structure January 24 2017 CLG835H...
Page 662: ...8 4 Electrical System January 24 2017 CLG835H...
Page 677: ...8 19 January 24 2017 Structure Function Principle CLG835H Power System P18E00014...