4-84
Testing and Adjustment
January 24, 2017
Pressure test of work hydraulic system
CLG835H
Pressure inspection and adjustment of overload valve of bucket tilting large cham-
ber
1. Test method
Figures
Operation instruction
Tools
1. Remove the plug, install the
pressure measuring connec-
tor 30C3280; connect the
pressure gauge at pressure
measuring point;
Pressure gauge
(range 40MPa\
5800psi);
2. Start the machine and lift the
boom to the maximum posi-
tion (when diesel engine and
hydraulic oil is under normal
operating temperature, the
diesel engine will be in idle
running);
P18H00079
P18H00080