4-92
Testing and Adjustment
January 24, 2017
Pressure test of work hydraulic system
CLG835H
Adjustment for LS relief pressure of control valve
1. Test method
Note:
the pressure of main safety valve of control valve and the cut-off pressure of working pump should
be adjusted properly before adjusting the pressure of LS relief of control valve.
Figures
Operation instruction
Tools
1. Connect the pressure gauge
at pressure measuring point;
Pressure gauge
(range 40MPa\
5800psi);
P18H00097
LS Relief valve:
Adjustment method: using 2 open-
end wrenches of 17mm, one
wrench gets valve body stuck,
and the other unscrews the lock
nut. Adjust the valve rod with inner
hexagon wrench, turn it clockwise
for waxing and anticlockwise for
waning.
P18H00098