Wake Up
Outdoor
Back Home
Out Door
Back Home
Sleep
6:00
20°C
8:00
15°C
11:30
15°C
13:30
15°C
17:00
15°C
22:00
15°C
NO
Settings Options
Data Setting Function
Factory Default
A1
Measure temperature
calibration
Change value range -9°C to + 9°C
0.5°C Accuracy
Calibration
A2
Temperature control return
difference setting
Change value range 0.5°C to + 2.5°C
1°C
A3
External sensors limit
temperature control return
difference
Change value range 1°C to + 9°C
2°C
A4
Options of sensor control
N1:
Built-in sensor (high temperature protection close).
N2:
External sensor (high temperature protection close).
N3:
Built-in sensor control temperature, external sensor limit
temperature (external sensor detect the temperature is higher
than highest temperature of external sensor, thermostat will
disconnect relay, turn off load).
N1
A5
Children lock setting
0: Half Lock 1: Full Lock
0
A6
Limit value of high
temperature for external
sensor
1.) 35°C - 75°C
2.) Under 35°C, screen display , high temperature
protection was cancelled.
45°C
A7
Limit value of low
temperature for external
sensor (anti-freeze
protection)
1.) 1°C - 10°C
2.) Exceed 10°C, screen display , low temperature
protection was cancelled.
5°C
A8
Setting temperature lowest
limit
1°C - 10°C
5°C
A9
Setting temperature highest
limit
20°C - 70°C
35°C
AA
Descaling function
0: Close descaling function.
1: Open descaling function ( valve is continuously closed
over 100 hours, it will be opened for 3 minutes automatically.
0: Close descaling
function
Ab
Power with memory function
0: Power with memory function.
1: Shutdown power after power off
2: Shutdown power after power on
0: Power with
memory function
AC
Weekly programming
selection
0: 5 + 2 ( 5 we 2 weeekend days) etc.
1: 6 + 1
2: 7
0: 5 + 2
Ad
Restore to factory defaults Displaying A0, press key until whole LCD
show all icons
Thermostat Program Mode
There are 3 period modes: 5 (weekdays) + 2 (weekend days), 6 + 1 and 7 days. Choose period of your
choice by long pressing for 3-5 secs. Enter into prgrammable mode. Then short press
choose: hour, minute time period and press and to increase and decrease values.
Once finished setting after 10 seconds thermostat will automatically save & exit.
Advanced Options
The optimum comfort temperature is 18°C - 22°C
With the thermostat turned off, long press for 3-5 secs. to access advanced settings.
From A1 to AD short press to toggle through the options. Adjust data by using the up
and down arrows. Short press to go to next option. After about 5 secs. the thermostat
will save & exit on its own.
OK