Assembly instructions | LK Electric Boiler 11-n
Settings
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
16A
20A
25A
35A
50A
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
7-levels
6-levels
5-levels
4-levels
Main fuses’ rating size.
Supply setting 20A.
Circulation pump’s
drive mode:
continuous
supply setting
summertime drive mode
Maximum number of capacity
levels for the boiler.
Each level corresponds to
1.6 kW. See following table.
Supply setting 7 levels:
11 kW.
Fuse
Fuse
Fuse
Fuse
Fuse
Output
level
Output Cur-
rent L1
Cur-
rent L2
Cur-
rent L3
Output
group
kW
A
A
A
1; 15% 1,6
3,9
3,9
0
1
2; 30% 3,1
3,9
3,9
7,8
2
3; 45% 4,7
6,8
6,8
6,8
1 + 2
4; 55% 6,3
9,1
9,1
9,1
3
5; 70% 7,9
13
13
9,1
1 + 3
6; 85% 9,4
13
13
16,9
2 + 3
7;
100%
11
15,9
15,9
15,9
1 + 2
+ 3
Remote control: Switch 1 in position ON, see item
Remote control.
ON
OFF
Remote control
Switch 1
in position ON
7
Temperature setting in accordance with item 8,
applies when inlet is open. When inlet is shut, or-
dinary temperature setting applies.
Temperature
setting when
regulated via
remote control
8
Switching off: Switch 1 in position OFF, see item
Switching off
.
ON
OFF
Off switch 1
in position OFF
7