6
GB
Instruction Manual Pressing Tool
authorised
copy
4.4 Service and maintenance instruction
The reliable performance of the tool is dependent on careful treatment and service. This represents an important
condition to safeguard a lasting connection. To safeguard this the tool have to be maintained and serviced regularly.
We would like to draw your attention to the following points:
1. The electric-hydraulic pressing unit have to be cleaned and dried after each use before being put into the transpor-
tation case.
2. In order to guaranty a proper function of the machine the pressing tool should be returned to the manufacturer or
one of our Authorized Service Centers (ASCs) after the red LED indicates Service (after 10.000 pressing cycles)
or once every year whatever occures
fi
rst.
3. The bolt joins, the rollers and their guides as well as the moveable parts of the pressing jaw must be oiled regularly
in small amounts.
4. Check through test compressions or have the tool manufacturer check the tool and pressing jaws regularly for
proper function.
5. Keep pressing jaws clean. Remove dirt with a brush.
In order to avoid possible malfunctions we offer you a manufacturer service consisting (see ASC) of disassembly,
cleaning, exchange of possibly worn out parts assembly and
fi
nal control. Only a clean and properly functioning press
system can over the time safeguard a leaking free connection.
Within the determined use of the tool only the pressing jaws (page I, pic. 1.8; page III, pic. 13) are permitted to be
changed by the customers.
Attention
Do not damage the seals of the tool. If the seals are damaged the warranty is invalidated.
5. Troubleshooting
a.) Constant
fl
ashing/indicating of the light diode display (page I, pic 1.3) or the occurence of an acoustical warning
signal.
see table 1. If the failure can not be solved return the tool to the nearest service
center (see attachment ASC 1-6).
b.) The tool loses oil.
Return the unit to the manufacturer. Do not open it and damage the seal of the tool.
c.) The red LED
fl
ashes 3x and simultaneously 3 acoustic warning signals occure (see table 1).
Serious fault! If this fault occures repeatedly return the unit to an Autorized Service Center (ASC). Do not open
it and damage the seal of the tool.
In case of a one time occurence the
fi
tting has to be dismantled or pressed a second time.
HE.16074_B © 08/2014
MAP2L19LK