background image

1 (8)

temperature is achieved to the radiators.  

Shutting-off against the return connection 

of the primary side is achieved by turning 

closed the outer and then the inner hex-

screw spindle.

3.  Thermostat with capillary tube connected 

sensor, length 2 m. 

4.  Feed connection from the primary side, ¾” 

male EuroCone. Connectors for 15 mm Cu 

are supplied.

5.  Return connection to the primary side, ¾” 

male EuroCone. Connectors for 15 mm Cu 

are supplied.

6.  Temperature limiter. Maximum limiter of 

the feed temperature to the under floor 

heating.

7.  Return valve (dim. 8 mm hex.).

8.  Connection ½” female thread for system 

refill upon installation.

9.  Ventilation valve with hose nipple.

10. VF valve (dim. 8 mm hex.). Must only be 

used for installations with low available 

drive pressure from the circulation pump of 

the primary side.

11. Circulation pump, Wilo Yonos Para 

RSB15/6-RKA with automatic speed con-

trol.

12. Connection feed floor heating ½” female 

thread.

13. Connection return floor heating ½” female 

thread.

14. Bracket

12

13

11

8

7

5

4

2

1

3

10

9

6 14

Design

The LK Minishunt M60 is intended for use in 

smaller under floor heating areas (up to 60 m² de-

pending on heating requirements/laying proce-

dures etc.) and is connected to an existing heating 

system. The shunt unit consists of an automatic 

speed-controlled circulation pump for the under 

floor heating circuit, a maximum limit function 

for the feed temperature, a return valve for the 

under floor heating circuit, a fill/discharge and 

air bleed valve plus a thermostatic valve unit, fit-

ted with a thermostat and a sensor, connected to 

a capillary tube. 

Connectors for a under floor heating circuit and 

mini manifolds for 2, 3 or 4 under floor heating 

circuits are provided as accessories. Possible pipe 

connections for floor heating are dim. 8, 12, 16 

and 20 mm. The installation can be concealed in 

built-in or wall-mounted cabinets, see heading 

Installation cabinets

1.  Thermostat valve.

2.  Switching between single or twin pipe 

radiator systems and shutting-off against 

the return connection of the primary side. 

When delivered, the minishunt is set for a 

twin pipe radiator system with the outer 

hex-screw spindle (dim. 10 mm hex.) scre-

wed in and the inner hex-screw spindle 

(dim. 4 mm hex.) screwed out. For single 

pipe systems the outer hex-screw spindle is 

gradually screwed out until correct  

 LK Minishunt M60

EN.33.C.134.1512

Assembly instructions | LK Minishunt M60

Summary of Contents for Minishunt M60

Page 1: ...heating areas up to 60 m de pending on heating requirements laying proce dures etc and is connected to an existing heating system The shunt unit consists of an automatic speed controlled circulation pump for the under floor heating circuit a maximum limit function for the feed temperature a return valve for the under floor heating circuit a fill discharge and air bleed valve plus a thermostatic va...

Page 2: ... connection The minishunt s primary connection is provided with a EuroCone thread Pipe connection to the primary side is made using the enclosed fit tings for 15 mm Cu Connectors for Cu 12 mm and to PEX PAL pipes dimension 16x2 20x2 and 20x2 8 mm are available as accessories The secondary connections of the minishunt have female thread The under floor heating pipes are connected for a floor heatin...

Page 3: ...ctric LK Actuator and is installed according to the se quence below Click Assembly of supplied thermostat To install the supplied thermostat with capillary tube connected sensor dismantle the hand actua tor and the black threaded adapter according to the sequence below The capillary tube connected sensor is preferably placed on a interior wall As accessory a thermostat with 5 m capillary tube alte...

Page 4: ...adjustment should be carried out as described below If the available drive pressure and flow on the primary side are known the theoretical adjust ment for the minishunt can be calculated refer to the project planning instructions for LK Floor Heating 1 Carry out air bleeding of the floor heating system and the minishunt as shown above Installation cabinets To conceal the installation there are cab...

Page 5: ...eeds for 10 min The venting routine is indicated with a fast flashing green diode light After completing the venting process the con stant pressure curve that best matches the requirements of the system is chosen See capacity chart below 3 Set the switch 2 for single or twin pipe radiator systems twin pipe radiator sys tem is factory set at delivery For single pipe systems the outer hex screw spin...

Page 6: ... pump s automatic venting routine to remove accumulated air in the pump s rotor chamber The automatic venting routine start after 3 seconds and lasts for 10 minutes Venting routine indicated by a fast flashing green diode light After complete venting choose the constant pressure curve that best matches the re quirements of the system see capacity chart be low If no choice is made the pump operatio...

Page 7: ...y replace the pump Trouble shooting The under floor heating circuit does not get warm Check that the shut off valves for 2 and the return valve 7 are open Check the setting on the maximum limiter valve 6 Check the connection operation and setting of the circulation pump If the above adjustments have been performed and there is still no heat reaching the under floor heating circuit this can be an i...

Page 8: ...2x58m 2x69m 3x54m 3x61m 3x69m 4x58m 4x63m 4x69m 5 Clip Rail 16 c c 160 mm 1x35m 1x70m 1x105m 2x70m 2x88m 3x70m 3x82m 3x93m 4x79m 4x88m 4x96m 6 Clip Rail 20 c c 300 mm 1x19m 1x38m 1x57m 1x76m 2x48m 2x57m 2x67m 2x76m 3x57m 3x63 3x70m 3x76m 7 HeatFloor 22 pipe dim X16 c c 200 mm 1x29m 1x57m 2x43m 2x57m 2x70m 3x57m 3x67m 3x76m 4x64m 4x70m 4x78m 4x85m 8 Floor Joist Plate 16 c c 200 mm 1x29m 1x57m 2x43m...

Reviews: