3

EN-33.C.14.3-6.0501

Channel 1

Channel 2

Channel 3

Channel 4

Reset P

ower

Cq

Antenna holder to be 
placed on the wall 
a minimum of 
200 mm from 
metal objects

Antenna hold

er

160 mm

25 mm

Activating the receiver

For Cq 4 and Cq 6 as follows:
• To activate the memorizing phase on the receiver unit, 
  press the button for the channel that is to be activated 
 

Þ

 rst. A weak sound signal is heard and the indicator 

  light will come on.
 
For Cq 1 as follows:
• To activate the memorizing phase on the receiver unit, 
  press the button     . A weak sound signal is heard 
  and the indicator light will come on.

Activating the room thermostat

•  Press and hold the lower black button (B).
• Brie

ß

 y press the upper black button (C).

•  When the indicator light (D) is lit, release the lower 
  button. Memorizing (the connection) between the 
  thermostat and the channel selected now occur. Pay 
  attention to the receiver. Once contact is established, 
  the sound signal will cease and the indicator light will 
 go 

out.

•  Press the upper button on the room thermostat one 
  more time to switch off the indicator light. (The indicator
  light on the thermostat in future use is only used to 
  warn of low battery power.)

Function control  

Place the room thermostat in the room where it is intended
to be assembled according to the design. By turning the 
thermostat’s adjustment dial, the indicator light on the 
receiver’s channel will be lit or switched off respectively 
within approximately 30 seconds.
•  Dial towards maximum temperature, the light on the 
  receiver unit comes on.
•  Dial towards minimum temperature, the light on the 
  receiver unit goes off.

  NB: The receiver Cq 1 works the opposite way.

If the light switches off when it should come on, check 
that the mains switch’s setting is in the lower position 
towards the heat symbol. See the section LK Room 
Thermostat Cq. If the setting was right and the problem 
continues, see the section ”Heat/Cool”.

NB: During set up (only) the indicator light on channel
4 or channel 6 comes on when one or more other 
channels trigger the heating. This function continues 
until all the channels are activated. For more informa-
tion, see the section “Pump Control”.

ADDITIONAL MEASURES

Assembling the room thermostat

Open the room thermostat by pulling the temperature scale
dial right out and loosening the screw that becomes visible.
Bend out the upper part to the left until it becomes loose. 
Position the room thermostat as per the design plan.

For the room thermostat to function properly, the fol-
lowing guidance should be followed:
•  Mount it on an inner wall where it is ventilated but not 
  in a draught. (NOTE FOR UK: in some home refurbish-
  ment projects where the building is poorly insulated, it
  may be prudent to place the thermostat on an outside, or
  coldest, wall. The thermostat will then compensate by
  calling for heat.)
•  Do not expose it to direct sunlight or other heat sources.
•  Mount it approximately 1.5 metres above the 

ß

 oor.

•  Do not mount it near a radio, TV or other transmitter.
•  Do not mount it near metal objects, such as metal doors,
  metal cupboards or similar.

Completing activation / memorizing

Continue activation / memorizing in the same way as for
the other channels, following the instructions for the 
LK Room Thermostat Cq.

LK Antenna Cq  

The LK Antenna Cq is intended to be used when the radio
connection between the room thermostat and the receiver
unit is unsatisfactory.

The antenna is assembled as follows:
•  The antenna holder is supplied with self-adhesive tape
  and is attached to the top of the receiver unit. The 
  stripped part of the antenna is pulled through the 
  antenna holder until it appears on the other side.
•  The other end of the antenna is pulled to the outside 
  of the enclosure and is assembled in the same way, 
  placed at least 200 mm from any metal objects.

!

Summary of Contents for Cq

Page 1: ...r 1 control zone LK Cq 4 for a maximum of 4 control zones channel 1 4 LK Cq 6 for a maximum of 6 control zones channel 1 6 The receiver unit functions along the same principles but theCq1unit whichonlyhasonereceiverchannel differs somewhat in its design The instructions for this model therefore contain a few additions REQUIREMENTS AsuitablyqualiÞedelectricianorinstallationengineer must carry out e...

Page 2: ...ght actuators can be connected Up to two actuators can be connected direct to Cq1 However if necessary it is possible to connect up to eight actuators to Cq1 by using an external wiring junction box In both cases the actuators are connected parrallel to each other and in line between terminal 9 and the LK Transformer Fig 3 Circuit diagram Cq 1 M Actuator LK Transformer 230 24 V AC A transformer 60...

Page 3: ...rds the heat symbol See the section LK Room Thermostat Cq If the setting was right and the problem continues see the section Heat Cool NB During set up only the indicator light on channel 4 or channel 6 comes on when one or more other channels trigger the heating This function continues until all the channels are activated For more informa tion see the section Pump Control ADDITIONAL MEASURES Asse...

Page 4: ...ess the Reset button and the button for Channel 4 at the same time First release Reset followed by Channel 4 NB FortheCq1unit thechangeismadeontheroom thermostat Alarm Whenafaultoccurs theindicatorlightbeginstoßashwith anirregulartimeintervalandasoundsignalisheard During signaldisruption theaffectedchannelwilldeliverapproxi mately 70 heat output Temporary interruption If no signal is received from...

Page 5: ... Room Thermostat Controloccursusingpulsewidthmodulation PBM which isintendedforactuators Thecontrolsignal whichiscalcu lated from the difference between the actual temperature and the temperature entered is emitted in the form of a signal with different pulse and rest ratios The sum of the signal and rest period is always 10 minutes With large temperature variations the thermostat is constantly sw...

Page 6: ...pproximately 3 years Control function PBM optional 2 point Cycle time approximately 10 minutes total on and off time Measurement interval approximately 10 minutes Type Heat Cool Valve exercising Once a day for 3 minutes can be switched off BR1 Temperature sensor NTC Transfer frequency 868 MHz Modulation FM Aerial Intern Transmission interval 10 minutes Range typical 100 metres free air or 2 ßoors ...