2 (9)

Connecting the electric valve

Attach the electric valve cable connector to the 

master unit. Connect the electric valve for cold 

water to contact 9 and the electric valve for hot 

water to contact 8. 

NOTE! DIP switch no. 6 should be switched to 

ON to activate monitoring of the hot water electric 

valve. 

If the electric valve's cables have been extended, 

the spring terminals can be used instead. These 

terminals have the same numbers as contacts 8 

and 9. Connect the red cable to R and the black 

cable to B.

DIP switches

The master unit has a row of DIP switches at pos 

12 with the following functions:

• Select between NC and NO depending on which 

PIR sensor is in use. Default is NC. This can be 

changed to NO by switching DIP switch no. 1 to 

ON. 

• The alarm signal on the main unit can be switched 

of by switching DIP switch no. 2 to ON. 

• The value of the delay timer can be adjusted 

using DIP switches 3 and 4. Refer to the matrix 

below to set the desired length in hours. Default 

is 2 min. 

ON

3

2min

5min

30min

2h

4

3

4

3

4

3

4

• The temperature alarm can be deactivated by 

moving DIP switch no. 5 to ON. 

• Valve monitoring for the hot water valve is deac-

tivated on deliverl Activate by moving DIP switch 

no. 6 to ON.

When installing a electric valve in an existing sys-

tem, perform a pressure test using the tap water 

system's existing water pressure, and inspect all 

new joints.

If the system is installed in a new building, per-

form a pressure test at 1.43 x estimated pressure, 

i.e. 14.3 bar, and inspect all new joints.

Installing the master unit

Position the master unit close to the electric valves. 

The cables are about 0.8 m long and can be extended 

up to 3 m using the same cable area (2 x 0.5 mm2). 

Fit the antenna included in the socket on top of 

the master unit. Attach the master unit to the wall 

using suitable screws, install it in an installation 

cabinet. If the unit is placed in an LK Installation 

Cabinet, the master unit can be mounted using an 

LK Bracket WSS or LK Rail WSS Manifold Cabinet 

UNI.

Connecting the master unit 

Check that the unit’s power supply is not con-

nected and that the unit is not live. Remove the 

cover of the master unit. Be careful with the flexible 

cable that connects the cover to the circuit board. 

The cable is loosened by pulling out the connector 

from terminal 13 on the circuit board. When replac-

ing the cover, check that the polished contact pin 

faces upwards towards the antenna. Ensure the 

flexible cable is not twisted.

Terminals 4 and 9 are spring terminals. Press the 

button down to attach the cable. Terminals 10 and 

11 are screw terminals.

1
2
3

10
11

4
5
6
7
8
9

12

13

Power 12VDC
Sensor 3,5 mm
Power LED

B-Alarm
A-Alarm

BUS
Digital In
Pressure 2, Hot Water
Pressure 1, Cold Water
Valve 2, Hot Water
Valve 1, Cold Water

DIP Switches

Keypad

1 NC/NO

2 Alarm Sound

3 Timer Set

4 Timer Set

5 Low Temp A-Alarm

6 Hot Water Valve

14

Pressure Alarm Level

1 2

3 4 5 6

nc

no

com

nc

no

com

1

2

12

13

6

8

9

3

4

5

6

7

8

9

10

11

D

+
+

-

-

+

-

-

R
R

B
B

14

EN.40.C.9.1911

Installation guide | LK Water Safety System WSS PIR

Summary of Contents for WSS PIR

Page 1: ...s etc A leak detector can also be fitted where there is a risk of leaks The system is developed to be user friendly and reliable System description The LK Water Safety System WSS PIR consists of a master unit a PIR motion detector and two electric valves Additional motion and leak detectors can be added to the system When the PIR sensor detects motion it gives a signal to the master unit which ope...

Page 2: ... per form a pressure test at 1 43 x estimated pressure i e 14 3 bar and inspect all new joints Installing the master unit Position the master unit close to the electric valves The cables are about 0 8 m long and can be extended up to 3 m using the same cable area 2 x 0 5 mm2 Fit the antenna included in the socket on top of the master unit Attach the master unit to the wall using suitable screws in...

Page 3: ...the required number of holes in the rub ber gasket for cable penetration Use the cable ties supplied for strain relief Secure the cable tie in the hole pattern in the black rubber gasket Replace the cover Screw the cover back onto the main unit Ensure the flexible cable is not twisted When all of the units to be connected with bus communication have been connected connect the master unit s network...

Page 4: ...e to D and The cable should be twinned type 2 x 0 5 mm2 D D Terminal on the leak detector for bus communication Place the leak detector at a suitable height from the floor so the sensor cable can reach down to its location The detector should be easy to access for changing batteries and to reset any alarms that are indicated with a sound and diode lights Secure the leak detector with suitable scre...

Page 5: ... seconds to reset the alarm Operating instructions Installing a LK Water Safety System reduces the risk of water damage in a property The system is controlled and monitored by the master unit A leak detector and PIR sensor are connected to the master unit Keys There are three keys on the master unit used for controlling the system When a key is pressed it will light up or flash Water open Open Ind...

Page 6: ...ity In the event of an alarm If an alarm occurs identify which unit it is for and the cause A alarms Reset the leak detector s water alarm by pressing the red key on the underside of the leak detector The sensor may also need to be dried or the alarm will recur Cut off a temperature alarm by pressing the red key on the underside of the leak detector The diode stops flashing when the temperature ri...

Page 7: ...e or the Quick Guide Removing units from the system If removing a unit from the system the system will have to be reset Refer to Resetting the System The relevant units can then be reprogrammed Resetting the system Reset the system to default settings on the master unit as follows 1 Disconnect power to the master unit 2 Press the Timer key 3 Reconnect the power at the same time as hold ing down th...

Page 8: ...very installation should therefore be tested indi vidually Environment LK Systems is affiliated with El Kretsen for collect ing and recycling electronics and batteries Used batteries should be sorted as batteries or small bat teries and deposited for battery recycling When the system has reached the end of its life it should be sorted as electronics or other electronics and deposited with a recycl...

Page 9: ...ensor WSS RSK 188 25 44 LK Sensor with branch cable WSS RSK 188 22 22 LK Branch Cable WSS RSK 188 22 23 LK Extension Cable WSS RSK 188 22 88 LK Bracket WSS Manifold Cabinet UNI RSK 188 22 21 LK Rail WSS Manifold Cabinet UNI RSK 188 23 21 LK Systems AB Box 66 161 26 Bromma Sweden www lksystems se en Installation guide LK Water Safety System WSS PIR EN 40 C 9 1911 ...

Reviews: