9 (9)

Accessories

LK Leak Detector WSS

RSK 188 22 97

LK Adapter 5V

RSK 188 22 89

LK Electric valve 12V

RSK 188 23 08 G15 
RSK 188 22 86 G20
RSK 188 24 03 G25

LK PIR sensor WSS

RSK 188 25 44

LK Sensor with branch cable WSS

RSK 188 22 22

LK Branch Cable WSS

RSK 188 22 23

LK Extension Cable WSS

RSK 188 22 88

LK Bracket WSS Manifold Cabinet UNI

RSK 188 22 21

LK Rail WSS Manifold Cabinet UNI

RSK 188 23 21

LK Systems AB, Box 66, 161 26 Bromma, Sweden | www.lksystems.se/en

Installation guide | LK Water Safety System WSS PIR

EN.40.C.9.1911

Summary of Contents for WSS PIR

Page 1: ...s etc A leak detector can also be fitted where there is a risk of leaks The system is developed to be user friendly and reliable System description The LK Water Safety System WSS PIR consists of a master unit a PIR motion detector and two electric valves Additional motion and leak detectors can be added to the system When the PIR sensor detects motion it gives a signal to the master unit which ope...

Page 2: ... per form a pressure test at 1 43 x estimated pressure i e 14 3 bar and inspect all new joints Installing the master unit Position the master unit close to the electric valves The cables are about 0 8 m long and can be extended up to 3 m using the same cable area 2 x 0 5 mm2 Fit the antenna included in the socket on top of the master unit Attach the master unit to the wall using suitable screws in...

Page 3: ...the required number of holes in the rub ber gasket for cable penetration Use the cable ties supplied for strain relief Secure the cable tie in the hole pattern in the black rubber gasket Replace the cover Screw the cover back onto the main unit Ensure the flexible cable is not twisted When all of the units to be connected with bus communication have been connected connect the master unit s network...

Page 4: ...e to D and The cable should be twinned type 2 x 0 5 mm2 D D Terminal on the leak detector for bus communication Place the leak detector at a suitable height from the floor so the sensor cable can reach down to its location The detector should be easy to access for changing batteries and to reset any alarms that are indicated with a sound and diode lights Secure the leak detector with suitable scre...

Page 5: ... seconds to reset the alarm Operating instructions Installing a LK Water Safety System reduces the risk of water damage in a property The system is controlled and monitored by the master unit A leak detector and PIR sensor are connected to the master unit Keys There are three keys on the master unit used for controlling the system When a key is pressed it will light up or flash Water open Open Ind...

Page 6: ...ity In the event of an alarm If an alarm occurs identify which unit it is for and the cause A alarms Reset the leak detector s water alarm by pressing the red key on the underside of the leak detector The sensor may also need to be dried or the alarm will recur Cut off a temperature alarm by pressing the red key on the underside of the leak detector The diode stops flashing when the temperature ri...

Page 7: ...e or the Quick Guide Removing units from the system If removing a unit from the system the system will have to be reset Refer to Resetting the System The relevant units can then be reprogrammed Resetting the system Reset the system to default settings on the master unit as follows 1 Disconnect power to the master unit 2 Press the Timer key 3 Reconnect the power at the same time as hold ing down th...

Page 8: ...very installation should therefore be tested indi vidually Environment LK Systems is affiliated with El Kretsen for collect ing and recycling electronics and batteries Used batteries should be sorted as batteries or small bat teries and deposited for battery recycling When the system has reached the end of its life it should be sorted as electronics or other electronics and deposited with a recycl...

Page 9: ...ensor WSS RSK 188 25 44 LK Sensor with branch cable WSS RSK 188 22 22 LK Branch Cable WSS RSK 188 22 23 LK Extension Cable WSS RSK 188 22 88 LK Bracket WSS Manifold Cabinet UNI RSK 188 22 21 LK Rail WSS Manifold Cabinet UNI RSK 188 23 21 LK Systems AB Box 66 161 26 Bromma Sweden www lksystems se en Installation guide LK Water Safety System WSS PIR EN 40 C 9 1911 ...