May 5, 2005
C:\Documents and Settings\timmartin\Local Settings\Temporary Internet Files\OLK9\CA
045 LMI 241-BWV2 to 440 or 501.doc
Page 4 of
12
7.
The “Configure Gages” screen needs to be set as follows. Failure to set this screen properly may
cause undesired results.
*NOTE: The default unit of measurment is MM. To change the unit of measurment to English the value
for “Scale:” needs to be entered as .3937 in step 9
8.
If changes to this screen are needed, press
▲
or
▼
to highlight either “Type”, “Master Type”,
“Master With”, or “Zero Before Read” then press <enter> to toggle the different choices. Refer to
the collector manual for further details of the configuration choices.
9.
To make changes to the “Scale” or “Zero Master” press
▲
or
▼
to highlight “Scale” or “Zero
Master” and press <enter>. This will bring up the numeric keypad.
“Gage Port G2” must
be matched to “Master
with G3” to calibrate
both flush and gap at
the same time.
If the “Gage Port” is
set to “G2a” then the
“Master” needs to be
“G3a”