Chapter 3: Procedures
3-49
HYDROBAR EXPRESS 220
Setting the Remnant Vise Alignment
This procedure is used for setting the alignment of the remnant vise.
Tools List:
•
6mm allen socket and ratchet
•
3mm hex key or T-handle
•
Unchamferred remnant that matches pusher collet
Procedure
Conditions:
•
Main guiding channel open
•
Preferred channel size installed: 14 – 21 mm
Step 1: Loosen the two thumb screws located on the pusher support brackets.
Thumb screws
Thumb screws
Pusher support brackets
Step 2: Remove the pusher support brackets and place the pusher assembly directly into the pusher channel.
Step 3: Press STOP on the remote to clear any alarms.
Step 4: Remove the YV7A and YV5 plugs from the valves.
Remove brackets
YV7A
YV5