Chapter 1: Common Issues
HYDROBAR EXPRESS 220
1-12
Front Stopper Cannot Move Up
FRONT STOPPER
CANNOT MOVE UP!
POSSIBLE CAUSES:
-BAR STOCK PROTRUDES
FROM THE BACK OF
THE SPINDLE
-SQ1 SWITCH
MALFUNCTION
-MECHANICAL OR
PNEUMATIC FAILURE
Description:
The Front Stopper Cannot Move Up alarm occurs if, during the loading cycle, the measuring flap does not rise up to be detected by
proximity switch SQ1. The alarm is normally generated due to a mechanical obstruction preventing the flap from rising up.
Solution:
Press the HELP key on the remote control station. Press the F4 key (Page Down icon) twice.
Case Input Remote
Pendant
Solution
Check to see if there is a mechanical obstruction preventing the
measuring stop from rising up.
Make sure that the SQ1 switch is adjusted to within a sensing
distance of 0.5mm-1mm from the measuring stop.
Check that the air flow restrictor has not cut off the air supply to the
cylinder.
1
Bit 7 = 0
MODULE 0
76543210
0
If the input still does not turn on, the problem can be isolated to a
defective switch or defective cable. Replace the cable and switch.
2
Bit 7 = 1
MODULE 0
76543210
10000000
Alarm needs to be cleared. Press the STOP key on the remote
control station to clear the message and reset the alarm.
For case 1, after the solution has been completed, press the STOP key on the remote control station to clear the message and reset
the alarm.
Summary of Contents for Hydrobar Express 220
Page 61: ......
Page 143: ......
Page 147: ......
Page 156: ...Chapter 6 Spare Parts 6 9 HYDROBAR EXPRESS 220 Servo Motor Assembly ...
Page 161: ...6 14 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Hydraulic Pump Assembly ...
Page 163: ...6 16 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Diameter Adjustment Motor Assembly ...
Page 164: ...Chapter 6 Spare Parts 6 17 HYDROBAR EXPRESS 220 Air Regulator and Cable Passage Plate ...