Chapter 1: Common Issues
HYDROBAR EXPRESS 220
1-22
Vise Positioning Error
VISE POSITIONING
ERROR!
POSSIBLE CAUSES:
-CHAIN COUPLING
DEVICE MALFUNCTION
-DRIVING CHAIN MIS-
ADJUSTED
-MECHANICAL FAILURE
Description:
The Vise Positioning Error alarm occurs:
If input (I1.4 – SQ6) does not turn off during the remnant extraction sequence, when the chain cursor reaches the home position and
input (I1.5 – SQ7) turns on.
Or
If input (I1.4 – SQ6) does not turn on during the loading sequence, when the vise reaches the mechanical stop at the back of the “H”-
channel (at the same time the chain cursor reaches home position) and input (I1.5 – SQ7) turns on.
Solution:
Press the STOP key on the remote control station to clear the message and reset the alarm. The bar feed needs to be referenced.
Input Remote
Pendant
Solution
Bit 4
MODULE 1
76543210
Check the chain coupling device.
Check to see if the chain is broken.
Check SQ6 switch. May be mis-adjusted or defective.
Re-reference the bar feed.
•
Contact LNS America, Inc. for further information.