Bar Stock Not Extracted from the Collet
BAR STOCK NOT
EXTRACTED FROM THE
COLLET!
POSSIBLE CAUSES:
-EXTRACTION DEVICE
MALFUNCTION
-SIGNAL SWITCH SQ5
DEFECTIVE OR
MIS-ADJUSTED
-MECHANICAL FAILURE
Description:
The Bar Stock Not Extracted From The Collet alarm occurs when input (I1.3 – SQ5) is not detected after the bar has been extracted
from the collet of the bar feed. Before the guiding channel opens to load a new bar, the remnant check device confirms that the
remnant has been extracted from the collet of the bar feed.
Solution:
•
Check that the extraction device jaws are not broken.
•
Check the adjustment of SQ5, the switch should only activate when no bar is present in the collet of the bar feed.
•
Contact LNS America Inc. for further information.