Chapter 1: Alarms
HYDROBAR EXPRESS 220
1-33
Bar Stock Moving Forward during Headstock Reverse with Collet Open
BAR STOCK IS MOVING
FORWARD DURING
HEADSTOCK REVERSE
WITH COLLET OPEN
!
POSSIBLE CAUSES
:
-CUT-OFF TOOL BROKEN
OR NOT IN POSITION
-EXCESSIVE PUSHING
TORQUE
Description:
The Bar Stock Moving Forward alarm is generated when the bar feed detects any forward movement by the feeding pusher while the
collet of the lathe is open and the headstock reverses for regrip.
Solution:
Alarm needs to be cleared. Press the STOP key on the remote control station to clear the message and reset the alarm.
•
Check that the cut-off tool is still intact. If it is broken, it will need to be replaced before putting the bar feed back in automatic
production. If this alarm occurs often due to cut-off tools breaking, reduce the pushing torque in the menu
Parameters Related
to Servo Drive (Torques)
.
If the problem persists please contact LNS America, Inc. for further information.