Bar Stock Insertion Malfunction
BAR STOCK INSERTION
MALFUNCTION
!
POSSIBLE CAUSES
:
-WRONG SIZE COLLET
-BURRS ON BAR STOCK
-MECHANICAL PROBLEM
Description:
The Bar Stock Insertion Malfunction alarm occurs during the loading sequence when the bar is not properly inserted into the collet of
the feeding pusher.
Solution:
Alarm needs to be cleared. Press the STOP key on the remote control station to clear the message and reset the alarm.
•
Make sure that the collet is the correct size for the bar stock being ran.
•
Check that there are no burrs on the back of the bar stock. LNS recommends that a chamfer be put on the back end of the bar.
•
Check the alignment between the feeding pusher and the bar stock while it is doing the insertion. If alignment side-to-side is off
make sure that the pusher guiding channel installed has the correct orange head bolts. Refer to
(the note is in the bottom right hand corner).
If the problem persists please contact LNS America, Inc. for further information.