Chapter 1: Alarms
HYDROBAR EXPRESS 220
1-41
A2 Interrupted During Loading
SIGNAL A2 (LATHE IN
AUTOMATIC MODE)
INTERRUPTED DURING
LOADING CYCLE!
RESUME AUTOMATIC
CYCLE OF THE LATHE
AND THE BAR FEEDER.
Description:
The Signal A2 Interrupted During Loading Cycle alarm occurs whenever PLC input (I3.1) drops out during the loading cycle.
Solution:
Alarm needs to be cleared. Press the STOP key on the remote control station to clear the message and reset the alarm. Remove the
bar stock from the loading channel and reset the bar feeder and the lathe in automatic cycle.