Chapter 1: Common Issues
HYDROBAR EXPRESS 220
1-42
Safety Time for Part Feed Out
SAFETY TIME
FOR PART FEED OUT
ELAPSED!
POSSIBLE CAUSES:
-PROGRAMMING ERROR
-MECH. INTERFERENCE
-INTERFACE PROBLEM
Description:
The Safety Time For Part Feed Out Elapsed alarm occurs if the value set in
OVERALL PART LENGTH
is not reached within 1 minute
after the bar feed is commanded to feed out.
Solution:
Alarm needs to be cleared. Press the STOP key on the remote control station to clear the message and reset the alarm.
•
Make sure that value for the
OVERALL PART LENGTH
is correct.
•
Check for any mechanical obstruction that will not allow the bar feed to reach the feed out distance.
Contact LNS America, Inc. for further information.
Summary of Contents for Hydrobar Express 220
Page 61: ......
Page 143: ......
Page 147: ......
Page 156: ...Chapter 6 Spare Parts 6 9 HYDROBAR EXPRESS 220 Servo Motor Assembly ...
Page 161: ...6 14 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Hydraulic Pump Assembly ...
Page 163: ...6 16 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Diameter Adjustment Motor Assembly ...
Page 164: ...Chapter 6 Spare Parts 6 17 HYDROBAR EXPRESS 220 Air Regulator and Cable Passage Plate ...