3-14
Chapter 3: Procedures
HYDROBAR EXPRESS 220
Step 20: Reinstall the t-tube mounting plate. Do not tighten the four bolts yet.
Note:
Make sure that the plate is installed with the largest hole on top.
Step 21: Open the channel by pressing the yellow button on the YV2A a
ir valve.
T-tube
mounting plate
Step 22: Pull the alignment bar forward until it hangs out of the bar feed approximately 2 ft.
Press this
yellow button
YV2A
2’
Step 23: Relocate the back alignment block to the end of the bar in the channel