C H A P T E R 1 : A L A R M S
QUICK LOAD SERVO 65/80
1 - 7
A11 – Measuring cell SQ3 signal defective
MEASURING CELL SQ3
SIGNAL DEFECTIVE!
- CELL DEFECTIVE
- OBSTACLE DETECTED
- CELL OBSTRUCTED
A11
SQ3
Description:
The « measuring cell SQ3 signal defective » alarm occurs whenever the PLC detects input (I25 – SQ3)
during more than 1 second before the loading table goes up or down. The problem is generated when the
switch is obstructed, defective or if any obstacle is detected in the switch detecting range.
Solution:
In the working screen, press the
key on the remote control. Press the key corresponding to
Page
Down
until the
INPUTS
page is displayed:
Case Input Solution
1
SQ3 = 1
•
Remove any obstacle in the detecting range of the switch.
•
Check that the SQ3 switch adjustment.
2
SQ3 = 0
Press the STOP button on the remote control to reset the alarm.
Summary of Contents for Quick Load Servo 65
Page 1: ...Troubleshooting manual ENG 9 020 01 ANG ...
Page 43: ......
Page 61: ......
Page 67: ......
Page 96: ...CHAPTER 6 SPARE PARTS QUICK LOAD SERVO 65 80 6 27 020 005 413 QLS 65 80 Locking block ...
Page 99: ...CHAPTER 6 SPARE PARTS 6 30 020 005 703 QLS 65 80 Sub assembly drive QUICK LOAD SERVO 65 80 ...
Page 101: ...CHAPTER 6 SPARE PARTS 6 32 020 005 723 QLS 65 80 Sub assembly cogwheel QUICK LOAD SERVO 65 80 ...
Page 115: ...CHAPTER 6 SPARE PARTS 6 46 020 011 013 12 QLS 65 Assembly pusher ø12 QUICK LOAD SERVO 65 80 ...
Page 116: ...CHAPTER 6 SPARE PARTS QUICK LOAD SERVO 65 80 6 47 020 011 013 20 QLS 65 Assembly pusher ø20 ...
Page 117: ...CHAPTER 6 SPARE PARTS 6 48 020 011 023 6 QLS 80 Assembly pusher ø1 4 QUICK LOAD SERVO 65 80 ...
Page 118: ...CHAPTER 6 SPARE PARTS QUICK LOAD SERVO 65 80 6 49 020 011 023 12 QLS 80 Assembly pusher ø12 ...
Page 119: ...CHAPTER 6 SPARE PARTS 6 50 020 011 023 20 QLS 80 Assembly pusher ø20 QUICK LOAD SERVO 65 80 ...