C H A P T E R 1 : A L A R M S
QUICK LOAD SERVO 65/80
1 - 3
A01 – Emergency stop line open
EMERGENCY STOP
LINE OPEN!
POSSIBLE CAUSES:
-CONNECTION
-PROBLEM IN
CIRCUITRY A01
Description:
The « emergency stop line open » alarm occurs whenever the lathe or the bar feeder goes into an
emergency stop condition and does not receive signal (I16). The problem is generated anytime there is
an open in the safety circuit.
Solution:
In the working screen, press the
key on the remote control. Press the key corresponding to
Page
Down
until the
INPUTS
page is displayed:
Case Input Solution
1
K1 = 0
•
Check the emergency buttons state on the bar feeder and the lathe.
•
Check the PLC connection.
•
Check the wiring according to the electrical diagram.
•
Press the STOP button on the remote control to reset the alarm.
2
K1 = 1
Press the STOP button on the remote control to reset the alarm.
Summary of Contents for Quick Load Servo 65
Page 1: ...Troubleshooting manual ENG 9 020 01 ANG ...
Page 43: ......
Page 61: ......
Page 67: ......
Page 96: ...CHAPTER 6 SPARE PARTS QUICK LOAD SERVO 65 80 6 27 020 005 413 QLS 65 80 Locking block ...
Page 99: ...CHAPTER 6 SPARE PARTS 6 30 020 005 703 QLS 65 80 Sub assembly drive QUICK LOAD SERVO 65 80 ...
Page 101: ...CHAPTER 6 SPARE PARTS 6 32 020 005 723 QLS 65 80 Sub assembly cogwheel QUICK LOAD SERVO 65 80 ...
Page 115: ...CHAPTER 6 SPARE PARTS 6 46 020 011 013 12 QLS 65 Assembly pusher ø12 QUICK LOAD SERVO 65 80 ...
Page 116: ...CHAPTER 6 SPARE PARTS QUICK LOAD SERVO 65 80 6 47 020 011 013 20 QLS 65 Assembly pusher ø20 ...
Page 117: ...CHAPTER 6 SPARE PARTS 6 48 020 011 023 6 QLS 80 Assembly pusher ø1 4 QUICK LOAD SERVO 65 80 ...
Page 118: ...CHAPTER 6 SPARE PARTS QUICK LOAD SERVO 65 80 6 49 020 011 023 12 QLS 80 Assembly pusher ø12 ...
Page 119: ...CHAPTER 6 SPARE PARTS 6 50 020 011 023 20 QLS 80 Assembly pusher ø20 QUICK LOAD SERVO 65 80 ...