C H A P T E R 1 : A L A R M S
1 - 6
A04 – Bar feeder retracted or not locked in its working position
BAR FEEDER
RETRACTED OR
NOT LOCKED IN ITS
WORKING POSITION!
A04
SQ12
Description:
The « bar feeder retracted or not locked in its working position » alarm occurs whenever the PLC does
not detect input (I19 – SQ12). The problem is generated when the bar feeder is retracted in reduction
tube change position or if the retraction system is not locked.
Solution:
In the working screen, press the
key on the remote control. Press the key corresponding to
Page
Down
until the
INPUTS
page is displayed:
Case Input Solution
1
SQ12 = 0 Set the bar feeder back in operating position and lock it.
2
SQ12 = 1 Press the STOP button on the remote control to reset the alarm.
QUICK LOAD SERVO 65/80
Summary of Contents for Quick Load Servo 65
Page 1: ...Troubleshooting manual ENG 9 020 01 ANG ...
Page 43: ......
Page 61: ......
Page 67: ......
Page 96: ...CHAPTER 6 SPARE PARTS QUICK LOAD SERVO 65 80 6 27 020 005 413 QLS 65 80 Locking block ...
Page 99: ...CHAPTER 6 SPARE PARTS 6 30 020 005 703 QLS 65 80 Sub assembly drive QUICK LOAD SERVO 65 80 ...
Page 101: ...CHAPTER 6 SPARE PARTS 6 32 020 005 723 QLS 65 80 Sub assembly cogwheel QUICK LOAD SERVO 65 80 ...
Page 115: ...CHAPTER 6 SPARE PARTS 6 46 020 011 013 12 QLS 65 Assembly pusher ø12 QUICK LOAD SERVO 65 80 ...
Page 116: ...CHAPTER 6 SPARE PARTS QUICK LOAD SERVO 65 80 6 47 020 011 013 20 QLS 65 Assembly pusher ø20 ...
Page 117: ...CHAPTER 6 SPARE PARTS 6 48 020 011 023 6 QLS 80 Assembly pusher ø1 4 QUICK LOAD SERVO 65 80 ...
Page 118: ...CHAPTER 6 SPARE PARTS QUICK LOAD SERVO 65 80 6 49 020 011 023 12 QLS 80 Assembly pusher ø12 ...
Page 119: ...CHAPTER 6 SPARE PARTS 6 50 020 011 023 20 QLS 80 Assembly pusher ø20 QUICK LOAD SERVO 65 80 ...