© LNS FOX Instruction manual series WS (USA) pag. 22 of 28 - rev. 06-2014
d) reinstallation of the impeller
e) tight main screw
f) reinstallation of impeller case and
drainage ring
6.3.3. Seals Replacement
Main seal
•
Remove the seal
•
Remove completely possible residual of the old seal using a sharp blade
•
Degrease the surfaces with accuracy using alcohol or specific products.
•
Dry surfaces
•
Apply on the surface a light layer of cyanocrylate (Loctite or equivalent) and position the seal
along the perimeter.
19a) Remove the seal
b) Clean the surfaces
c) Apply seal
d) Remove safety protection screen
e) Remove seal
f) Reinstallation of safety protection
screen
“Safety of people”
Do not start the unit without having safety protection screen in place. It could otherwise result in
possible damages due to the rotation of the impeller.
•
Unscrew screws securing the safety protection screen
•
Remove seal of the safety protection screen
•
Apply the new seal on the safety protection screen
•
Mount the protection safety screen (along with the seal) onto the impeller case. Secure it with
screws.
6.3.4. Electric motor - Installation and removal
Removal
•
Remove the impeller as described in the general cleaning section
•
Unscrew the 4 screws securing the cover of the control panel box