16
Initially mount or adjust the SLA-3 position, please select the "adjustment
mode": Open the mode change access "ON", then press the mode
option button to select the "adjustment mode"
Please install the device in full compliance with the manual, otherwise
may lead to serious injury
Fig.4-4 Proper Mounting
【
Installation
】
The SLA-3 device bottom beam should be positioned at least 6mm on
top of the workpiece when the bending machine close at slow speed
≥ 6mm
Fig.4-3 Speed Switching Point Setting
bottom beam
4.4 Installation Position
Receiver
Emitter
Summary of Contents for SLA-3
Page 2: ......
Page 27: ...23 5 2 SLA 3 Wiring with safety relay Fig 5 1 SLA 3 Wiring With Safety Relay...
Page 32: ...28 Fig 6 2 Test Procedure Diagram upper mould STOP...