Technical specifications
General
Type
LOB-GW-HYB-WMBUS
Purchase name
Wireless M-Bus Gateway V3
Input Voltage
3.3V to 5V, 3.6V (standard)
Item number
8000162
Metering
Wireless M-Bus
S1, C1/T1 Mode
RX frequencies
868.3 MHz, 868.95 MHz
Standard
DIN EN 13757-4
Proprietary mode
Xylem SensusRF (BubbleUP)
Typ. range
30 m (Indoor), 2-3 floors
Typ. range
100 m (Outdoor), open space
Memory capacity
500 telegrams, each 100 bytes
Whitelist filter
ID, M-Field, CI-Field, Type
Configuration
collection duration and intervals
Cellular
LTE networks
Cat-NB1, Cat-NB2, Cat-M1
LTE bands
B3, B8, B20
TX power
≤
23 dBm
Typ. range
network-dependent
SIM card
4FF (Nano-SIM)
Data transfer
CoAP via UDP
Encryption
DTLS (optional)
Data format
CBOR bzw. JSON
LoRaWAN
Protocol
Class A LoRaWAN 1.0.2 EU868
TX power
≤
14 dBm
Activation
Over-the-air activation (OTAA)
Typ. range
up to 2 km, urban
Typ. range
up to 10 km, open space
Antenna
Internal type
multiband PCB monopoles
Ext. connector
on request
Battery
Approved type
SAFT LSH20
Voltage
3.6V
Other types
on request
Chemistry
Li-SOCl2
Capacity
≤
13 Ah
Cont. current
≤
1.8 A
Weight
≤
120 g
Connector
JST-XH 2-Pin
Mounting
3M hook and loop tape
Power
Normal / Idle
≤
11 mW
depends
RX Metering
≤
33 mW
on
RX LoRa
≤
33 mW
operating
TX LoRa
≤
110 mW
mode
RX NB-IoT
≤
162 mW
TX NB-IoT
≤
1.6 W
Sleep
≤
36
µ
W
Housing
Measurements
130 x 82 x 55 mm³ (incl. PCE)
Material
Polycarbonate
Screws
stainless steel V2A
Weight
≤
340 g (incl. battery)
Flammability class
960 °C V-2 (as per UL94)
Protection class
IP66 (0.3 bar / 30 seconds)
Color
white
Impact-
resistance
IK08
Environment
Rel. humidity
20...70 % (non-condensing)
Must be
Operating temp.
-20 °C to 55 °C
followed!
Storage temp.
0 °C to 30 °C
Installation height
≤
2 m (above ground)
Installation height
≤
2000 m (above sea level)