background image

Radio frequencies and bands used

Harmonized radio bands used by the gateway, max. occupied bandwidths

(BW) and transmission powers (TX power, EIRP). Unless otherwise indi-

cated, the specified frequencies are used for both the transmit (TX, UL)

and receive (RX, DL) directions.

Band

Modulation

BW

Frequencies

TX power

kHz

MHz

dBm

L

LoRa

125

867.1, 867.3, 867.5,

867.7, 867.9

14

M

LoRa

125

868.1, 868.3, 868.5

14

M

LoRa

250

868.3

14

P

LoRa

125

869.525

14

M

FSK

200

868.3

Only RX

M

FSK

200

868.42

Only RX

N

FSK

200

868.95

Only RX

B8

Cat-NB1|2

200

UL:880...915,

DL:925...960

23

B20

Cat-NB1|2

200

UL:832...862,

DL:791...821

23

B3

Cat-NB1|2

200

UL:1710...1785,

DL:1805...1880

23

B8

Cat-M1

1800

UL:880...915,

DL:925...960

23

B20

Cat-M1

1800

UL:832...862,

DL:791...821

23

B3

Cat-M1

1800

UL:1710...1785,

DL:1805...1880

23

Proper disposal of this product

In Germany and for products delivered directly from Germany:

Due to the applicable regulations, the electrical and electronic

devices of Lobaro GmbH may not be disposed of via the public

collection points for electrical devices!
In order to create possibilities for the return of old devices,

we cooperate with several qualified recycling companies. If

a device manufactured by us has become an old device and

you would like to return it, please contact:

https://www.take-e-way.de/leistungen/
elektrogesetz-weee-elektrog/b2b-altgeraete-ruecknahme-entsorgung

and fill out the questionnaire.

In countries of the European Union outside Germany:

Information on correct disposal can be obtained from your dealer or the

responsible distributor.

Safety instructions Lithium batteries

• Store protected from moisture

• Keep out of reach of children

• Do not heat above 85 °C

• Do not short circuit

• Do not open or damage

• Do not recharge

,

Batteries may only be replaced by qualified personnel. The

connector plug only fits in one position to ensure correct polar-

ity installation. Therefore, do not apply excessive force when

plugging in.

,

The battery may only be connected during regular operation.

Deep discharge due to persistent error conditions, e.g. if the

device cannot establish a connection or send data for long pe-

riods, must be avoided.

Warranty and guarantee

Warranty and guarantee claims can only be asserted if the device has been

used as intended and the technical specifications and applicable technical

rules have been observed.

Last updated: 06.04.2022

Summary of Contents for LOB-GW-HYB-WMBUS

Page 1: ...ncreased fire protection requirements e g staircases escape routes the installation company or the qualified personnel must ensure that the specific requirements according to local building regulations are fulfilled These instructions must be read carefully before initial opera tion followed and kept for the entire service life of the device Intended use The Lobaro Wireless M Bus Gateway V3 receiv...

Page 2: ...Meter reception can be restricted with filters to specific device IDs types or CI fields 5 After the configured period of time the collection of meter data by radio is stopped again 6 The data is sent via NB IoT cellular radio or LoRaWAN to the down stream IoT platform or LoRaWAN network server on the Internet 7 The platform decrypts on demand the consumption data with stored keys 8 The consumptio...

Page 3: ...e at https doc lobaro com The socket for an SD card 6 is suitable for holding a corresponding memory card The locking mechanism works analogously to the SIM card Only 3 6V batteries approved by Lobaro may be used with the gateway The use of other batteries especially without velcro fluff is not permitted as there would be no sufficient protection of the battery in the housing Only antennas approve...

Page 4: ...be maintained at all times The mounted pressure compensation element 9 increases the total width of the gateway from 122 mm in figure 3 to a total of 130 mm ð The pressure compensation element 9 and the IP66 housing protection class allow the gateway to be operated outdoors Simplified CE declaration Lobaro GmbH hereby declares that the LOB GW HYB WMBUS is in compliance with Directives 2014 53 EU a...

Page 5: ...X power 14 dBm Activation Over the air activation OTAA Typ range up to 2 km urban Typ range up to 10 km open space Antenna Internal type multiband PCB monopoles Ext connector on request Battery Approved type SAFT LSH20 Voltage 3 6V Other types on request Chemistry Li SOCl2 Capacity 13 Ah Cont current 1 8 A Weight 120 g Connector JST XH 2 Pin Mounting 3M hook and loop tape Power Normal Idle 11 mW d...

Page 6: ... return of old devices we cooperate with several qualified recycling companies If a device manufactured by us has become an old device and you would like to return it please contact https www take e way de leistungen elektrogesetz weee elektrog b2b altgeraete ruecknahme entsorgung and fill out the questionnaire In countries of the European Union outside Germany Information on correct disposal can ...

Reviews: