TS- I have an Over-Current or Feedback Sweep/ Elevation Error.
Trouble Shooting Instructions
Elite Models that Apply: Phenom 1 & 2
Step
Description
Tools
Picture
The more common statements regarding over-current
sweep and elevation issues are…
*The Control Panel should read: “Over-Current Sweep
Motor Error”. or “Over-Current Elevation Motor
Error”. ´´Feedback Elevation Error´´, or ´´Feedback
Sweep Motor Error´´.
*Before Taking the Upper Hopper Unit off, please
Make
sure the 4 Wings holding the Upper Hopper Unit to the
Base Unit are finger tightened, and not over tighten, for
over tightening these Wings can cause an Over-Current
Sweep Error.
•
“My machine has Over-current error
message.”
•
´´My machine has an Feedback error
message.´´
•
“My machine turns a lot then gets stuck to
the right.”
•
“My elevation moves all the way up and
stops after the elevation is pointing toward
the sky.”
This indicates one of the following:
•
The sweep is not finding home location.
(Section 1. Checking the Sweep Magnet).
•
The Elevation is not finding home location.
(Section 2. Checking the Elevation Magnet).
•
The wires have become loosened from the
vein harness.
(Section 3. Checking the
Sensor Connections).
•
The Sweep and Elevation Snap-In sensors
have become loosened from the motors.
(Section 4. Checking the Snap-In sensor
connections).
•
The Timing Discs are stuck, and need to be
rotated to free them.
(Section 5. Checking
Timing Discs).
Phillips Screw
Driver