Phone: 800.526.4041
Fax: 818.764.6061
Author: JJ Contributors: RR, CT Original Date:11/2/12 Revision: 2/17/2022
TS- I have an Over-Current or Feedback Sweep/ Elevation Error.
Trouble Shooting Instructions
Disconnecting The Phenom Hopper Unit and Base
Unit.
Step 1.)
Unscrew the 4 wing screws (D) and washers
(C) from the bottom of the Base Unit (E). (
Pull these
items out and set them aside for later use.
)
Step 2.)
Disconnect the Wire Connector (B) allowing
you to completely separate the Hopper Unit (A) from the
Base Unit (E). Use 2 people to carefully set the Hopper
Unit (A) upside down, so that the bottom plate is
exposed.
Lobster Phenom with
labeled components.
(Base Unit separate from
Hopper Unit).
Top Portion of Hopper
Unit upside down with
bottom plate exposed.
3
Removing The Hopper Unit Casing From The
Internal Platform Assembly
Step 1.)
CAREFULLY remove the 10 screws connecting
the Base Platform to the Hopper Unit.
(The Base
Platform Pims are very sensitive, use caution when
unscrewing these screws.)
Step 2.)
Remove the 4 black screws fastening the
control board to the Hopper Unit. Unplug the Feed Motor
wire and unscrew the ground wire (Diagram
A.
) on the
control panel.
Step 3.)
Using two people have one person lift the
Platform piece out of the Hopper Unit, while the other
person helps feed the control board assembly through
the hole, until you have the entire Platform Yoke
Assembly (with the control board) separated from the
Hopper Unit Case.
Phenom Internal Platform
Assembly being removed from
Upper Hopper Unit.
Diagram
A.)
Ground wire location. (Green)
Feed Motor location. (Red)