Author: JJ                   Contributors: RR, CT                             Original  Date:11/2/12                                              Revision: 2/17/2022  

TS- I have an Over-Current or Feedback Sweep/ Elevation Error. 

Trouble Shooting Instructions  

 

Sweep Pos quick disconnect 

(Red black and 

Orange

). 

 

 

4.

 

Diagram C. shows that the Sweep Home 
Wire (coming out of the chassis floor in 
front of the battery) connects to the Sweep 
Home plug (with the red, black, and yellow 
wires and Sweep Home label.).  

   

 

Sweep Home quick disconnect (red, black, and yellow 

wires). 

 

Diagram D.) 

Elevation Home connection red, black, and 

green. Coming from the Yoke assembly (just follow the 

vein harness until it reaches the Yoke).  

 

Summary of Contents for Phenom 1

Page 1: ...ened and not over tighten for over tightening these Wings can cause an Over Current Sweep Error My machine has Over current error message My machine has an Feedback error message My machine turns a lot then gets stuck to the right My elevation moves all the way up and stops after the elevation is pointing toward the sky This indicates one of the following The sweep is not finding home location Sec...

Page 2: ...pper Unit Top Portion of Hopper Unit upside down with bottom plate exposed 3 Removing The Hopper Unit Casing From The Internal Platform Assembly Step 1 CAREFULLY remove the 10 screws connecting the Base Platform to the Hopper Unit The Base Platform Pims are very sensitive use caution when unscrewing these screws Step 2 Remove the 4 black screws fastening the control board to the Hopper Unit Unplug...

Page 3: ...on the inner metal section of the Davit Center behind the white yoke spacer you can see the screw threading poking through the domed shape on the Davit Center marked in red in the diagram below 3 Take your paper clip or flat head screw driver tip and touch the screw thread you located If it attracts to the screw bottom then the magnet is in place Checking for Sweep Magnet 4 Using the image below y...

Page 4: ...tform poking through the slide slot 5 The Sweep Home sensor should be secured to the platform as shown in the image below in Red If the problem has not been resolved go to Section 3 Checking Sensor Connections Section 3 1 Check the elevation position sweep home and sweep position quick connections Make sure the labels match up The diagrams below only apply if your wires are unplugged Vein Harness ...

Page 5: ...ein Harness wires unplugged Vein Harness wires plugged in Vein Harness with disconnected terminal pictured above Follow quick connect instructions and Elev Pos quick disconnect Red black and blue wires B Sweep Pos quick disconnect Red black and Orange C Sweep Home quick disconnect Red black and yellow wires Diagram D Elevation Home connection red black and green Vein Sensor Harness circuit board c...

Page 6: ...ake sure all wires are connected to the correct harness plugs 2 Diagram A shows that the Elevation Wire coming from the elevation motor connects to the Elevation Position plug with the red black and blue wires and Elev Pos label Elev Pos quick disconnect Red black and blue wires 3 Diagram B shows that the Sweep Position Wire coming from the sweep motor connects to the Sweep Position plug with the ...

Page 7: ... Pos quick disconnect Red black and Orange 4 Diagram C shows that the Sweep Home Wire coming out of the chassis floor in front of the battery connects to the Sweep Home plug with the red black and yellow wires and Sweep Home label Sweep Home quick disconnect red black and yellow wires Diagram D Elevation Home connection red black and green Coming from the Yoke assembly just follow the vein harness...

Page 8: ...n the circuit board Disconnect this by pinching on the two longer sides and pulling up Blow it out and then reconnect it Checking the Timing Discs 1 Just above the Snap In sensor and little bit to the right of it there is a disc mounted on top of the motor This is known as the Timing Disc Sometimes the motor can seize up and the disc can become stuck in place This is generally fixed with the help ...

Page 9: ...ooting Instructions times If it feels like the disc is stuck in place go ahead apply a small amount of force to try and get it unstuck If the disc winds up and shoots back in the opposite direction then it may be possible that the motor will need to be replaced Elevation Motor Timing Disc highlighted in green Sweep Motor Timing Disc highlighted in green Sweep Motor Timing Disc highlighted in green...

Page 10: ...ugh the rear Circuit board side of the hopper 3 Check the Snap In Sensors located at the back portion of the Proxy Mount Assembly It is below the Proxy Mount Magnet Holder 4 Make Sure the sensor is plugged in all the way by grabbing the 3 wires red black and green and CAREFULLY pulling a little bit away from the Elevation Sweep Assembly If you feel any resistance then the snap in sensor is in plac...

Page 11: ...he Internal Platform Assembly with the Control Panel into the bottom of the Upper Hopper Unit Have one person reach in threw the control panel opening and direct the panel until it is hanging outside of the Upper Hopper Unit Step 2 CAREFULLY screw in the 10 screws connecting the Base Platform to the Hopper Unit The Base Platform Pims are very sensitive use caution when screwing in these screws Ste...

Page 12: ...to place when properly aligned Step 2 Use the 4 wings provided D and the 4 washes provided C to secure the Base Unit to the Hopper Unit from the underside as depicted in the picture to the right Make sure the 4 Wings are finger tightened and do not over tighten for over tightening these Wings can cause and Over Current Sweep Error If the issue continues upon putting the machine back together and t...

Reviews: