8
Ratings
Notes:
1. Copper-fin
2
pool heaters require special gas venting. Use only the vent materials and methods specified in the Copper-Fin
2
Pool Heater Installation and Operation Manual.
2. The
Copper-fin
2
is orificed for operation up to 2000 feet altitude, and including up to 4,500 feet, with no field adjustments.
The appliance will de-rate by 4% for each 1000 feet above sea level up to 4,500 feet. Consult the factory for installations above
4,500 feet elevation.
Maximum allowed working pressure is located on the rating plate.
NOTICE
Model Number
Note: Change “N” to
“L” for L.P. gas models.
Specifications
Appliance Water
Content Gallons
Water Connections
Gas Connections
Air / Vent
Sizes
(Note 1)
CPN0502
1.7
2"
1-1/4"
6"
CPN0652
2.0
2"
1-1/4"
8"
CPN0752
2.1
2"
1-1/4"
8"
CPN0992
2.2
2-1/2"
2"
10"
CPN1262
2.6
2-1/2"
2"
12"
CPN1442
2.9
2-1/2"
2"
12"
CPN1802
3.3
2-1/2"
2"
12"/14"
CPN2072
3.6
2-1/2"
2"
12"/14"
Installation & Operation Manual