GAS CONTROL VALVE/THERMOSTAT (160°)
BLACK ON/
OFF SWITCH
TEMPERATURE
SETTING DIAL
155°F
70°F
130°F
140°F
150°F
120°F
110°F
Figure 46.
Temperature
Dial Setting
Approximate
Temperature
°F
Time to induce a 2nd
and 3rd Degree burn
to adult skin
VERY HOT
155
Less than 1 second
C
150
About 1.5 seconds
B
140
Less than 5 seconds
A
130
More than 30 seconds
HOT
120
More than 5 minutes
LOW
110
Normal shower temp
VAC
70
N/A
Table 4.
Note:
The temperatures indicated are approximates. The
actual temperature of the heated water may vary.
The Vacation Setting (VAC) sets the controller at
approximately 70°F . This setting is recommended when
the water heater is not in use for a long period of time. This
effectively turns the controller temperature setting down to
a temperature that prevents the water in the water heater
from freezing while still conserving energy.
GAS CONTROL VALVE/THERMOSTAT (181°)
WHITE ON/
OFF SWITCH
TEMPERATURE
SETTING DIAL
181°F
70°F
140°F 155°F 165°F
130°F
110°F
Figure 47.
Temperature
Dial Setting
Approximate
Temperature
°F
Time to induce a 2nd
and 3rd Degree burn
to adult skin
VERY HOT
181
Less than 1 second
C
165
Less than 1 second
B
155
About 1.5 seconds
A
140
Less than 5 seconds
HOT
130
More than 30 seconds
LOW
110
Normal shower temp
VAC
70
N/A
Table 5.
Note:
The temperatures indicated are approximates. The
actual temperature of the heated water may vary.
The Vacation Setting (VAC) sets the controller at
approximately 70°F . This setting is recommended when
the water heater is not in use for a long period of time. This
effectively turns the controller temperature setting down to
a temperature that prevents the water in the water heater
from freezing while still conserving energy.