36
10.17
TYPE B
23
(CONVENTIONAL FLUE WITH FAN ASSISTANCE)
When the water heater is installed as a Type B
23
appliance, the flue system should be installed in accordance with the flue
manufacturer’s specific instructions.
Item No EKWCF001
FAN ASSISTED OPEN FLUE STARTER ASSEMBLY
Kit contains components to start the connection to the appliance only
MODELS EKW46CE,EKW61CE
COMPONENTS INCLUDED
Item No.
Description
Number
Quantity
M75256
AIR INLET TRANSITION Ø80mm ALU
1
1
M73039
AIR INLET GRILLE Ø80mm ALU
2
1
M85279
SAMPLING POINT Ø80mm PP
3
1
Item No EKWCF002
FAN ASSISTED OPEN FLUE STARTER ASSEMBLY
Kit contains components to start the connection to the appliance only
MODELS EKW86CE
COMPONENTS INCLUDED
Item No.
Description
Number
Quantity
M75257
AIR INLET TRANSITION Ø100mm ALU
1
1
M86787
APPLIANCE AIR INLET GUARD Ø100mm
2
1
M85189
SAMPLING POINT Ø100mm PP
3
1
The above is a kit of components to facilitate conventional flueing of the appliance and must be fitted prior to fitting any other flue
components.
1.Insert the exhaust transition into the exhaust port of the water heater.
2..Insert the flue temperature sensor into the location hole on the exhaust transition.
If the flue temperature sensor is not fitted, the flue gas may exceed the
maximum temperature rating of the flue and can lead to severe personal
injury, death or substantial property damage.
3.Insert the air intake into the intake connection and tighten the worm drive clip.
4.Insert the air inlet grill into the air inlet transition. For safety reasons this must be fitted prior
to operating the appliance.
10.17.1
TYPICAL
CONVENTIONAL
FLUE
ARRANGEMENT
Summary of Contents for ECOKNIGHT EKW116CE
Page 28: ...28 Max distance between brackets ...
Page 29: ...29 ...
Page 30: ...30 ...
Page 34: ...34 ...
Page 35: ...35 ...
Page 55: ...55 15 8 WIRING DIAGRAM 15 8 1 WIRING DIAGRAM ...
Page 56: ...56 15 9 LADDER DIAGRAM 15 9 1 LADDER DIAGRAM ...
Page 87: ...87 ...
Page 88: ...88 ...