MENU SET C:  DATA LOGGING 

 
Pressing the Down arrow followed by the Enter/Reset button will access the Data Logging menu set.  This menu 
set  has  three  options  that  will  display  recorded  data  about  the  operation  of  the  water  heater.    To  access  the 

options, use the 

Up

 or 

Down

 buttons followed by the 

Enter/Reset

 button. 

 

3.4.1

 

TOTAL HRS. RUN 

 
The Total Hrs. Run option shows the total time that the burner in the water heater has been operating for since the 
counter was last reset. 

 

3.4.2

 

IGNITION ATTEMPTS 

 
The Ignition Attempts option will show the number of times the water heater has attempted to fire since the counter 
was last reset. 

 

3.4.3

 

LAST 10 ERRORS 

 
The Last 10 Errors option will show the date, time and fault description for the last ten errors that caused the boiler 
the stop.  The 

Up

 or 

Down

 button should be used to scroll through the errors 

 

3.5

 

MENU SET E:  WHR SETTINGS 

 

Pressing the Down arrow 2 times followed by the Enter/Reset button will access the Water Heater Settings menu 
set.  This menu set has one option; to access the option press the 

Enter/Reset

 button.  

 

3.5.1

 

TANK SETPOINT 

 

The  Tank  Setpoint  parameter  allows  the  setpoint  of  the  water  heater  to  be  adjusted  when  a  flow  temperature 
sensor is not used.  Lochinvar Limited recommends that a flow sensor is always used with this appliance. 
 

The setpoint should be adjusted to ensure that the water is stored at 60°C and distributed at 50°C within 1 (one) 
minute at all outlets.  Care is needed to avoid much higher temperatures because of the risk of scalding.  At 50°C 
the risk of scalding is small for most people, but the risk increases rapidly with higher temperatures and for longer 

exposure times.  The risk to young children and to those with a sensory or mobility loss will be greater.  Where a 
significant scalding risk has been identified, the use of thermostatic mixing valves on baths and showers should be 

considered to reduce temperature, these need to be placed as close to the point of use as possible. 
 

The default value is 60

C.  To modify the temperature setting, the 

Up

 or 

Down

 button should be used and the 

Enter/Reset

 button pressed to store the desired setting. 

 

3.6

 

EXITING USER SETTINGS MODE 

 

To  exit  the  user-setting  mode,  the 

Menu/Exit

  button  should  be  pressed  whilst  in  the  Main  Menu  screen.  

Alternatively, if no button is pressed for 60 seconds, the water heater will revert to its  normal operating screen.  

Once this has occurred, the 

Enter/Reset

 button should be pressed to switch the unit on. 

Summary of Contents for EKW115CE

Page 1: ...EcoKnight range High Efficiency Gas Fired Condensing Water Heaters User SMART SYSTEM Control Guide Models EKW45CE EKW60CE EKW85CE EKW115CE EKW145CE EKW175CE EKW205CE EKW235CE INS0012 Issue No 5 August 2011 ...

Page 2: ...CONTROL PANEL 5 2 3 SEQUENCE OF OPERATION 6 2 4 STATUS DISPLAY SCREENS 7 3 0 USER SETTINGS 9 3 1 GENERAL 9 3 2 ENTERING THE USER CODE 9 3 3 MENU SET A GENERAL SETTINGS 9 3 3 1 WATER HEATER MODEL 9 3 3 2 USER CODE 9 3 3 3 TIME DATE 10 3 3 4 SOFTWARE VERSION 10 3 3 5 TEMPERATURE UNITS 10 3 3 6 NIGHT SETBACK TEMPERATURE 10 3 3 7 NIGHT SETBACK TIME 10 3 4 MENU SET C DATA LOGGING 11 3 4 1 TOTAL HRS RUN...

Page 3: ...ROCEDURE FOR SHUTTING DOWN To take the appliance out of service the Enter Reset button should be pressed If the appliance in to be shut down for a long period of time the power supply should be isolated using the rocker switch on the back and the gas supply should be isolated at the gas inlet appliance isolating valve 1 4 TEMPERATURE ADJUSTMENT PROCEDURE The setpoint can be adjusted using the Up a...

Page 4: ...UPPLY When installed as a conventionally flued appliance the room in which the appliance is installed must be ventilated Blocking these air vents may lead to severe injury serious property damage or death The area in which the appliance is installed should not be used to store any other materials 1 8 CONDENSATE DRAIN The condensate drain must not be blocked or modified in any way If fitted with a ...

Page 5: ...ROL 2 1 GENERAL The Lochinvar EcoKnight uses the SMART SYSTEM control interface The control panel display gives information on set up system status and diagnostic data in words rather than codes 2 2 SMART SYSTEM CONTROL PANEL ...

Page 6: ...cle is complete and the blocked drain and auto reset high limit are closed the control starts the 5 second trial for ignition by sending spark voltage to the spark electrode and opening the gas valve WHR IGNITION OUT 61 5C 65 5 If the control does not detect flame by the end of the trial for ignition the control performs a 10 second postpurge On the EKW45CE to EKW115CE models the control will perf...

Page 7: ... the unit to fire at 100 of rate for the purpose of combustion analysis OUT C The outlet temperature is displayed OPEN The control does not detect the outlet sensor SHORTED The outlet sensor wires or the sensor itself has become shorted Press the Next arrow key on the SMART SYSTEM display to access Screen 2 2 IN C If a tank sensor is installed only the inlet temperature will be displayed C When a ...

Page 8: ... a tank sensor Cas No Members The Master control could not detect any Member controls to participate in the Cascade PMP Off The Master control has not received a call for heat from a tank sensor and has not powered the primary pump PMP On The Master control has received a call for heat from a remote thermostat and has powered the system pump PMP Delay The tank call for heat has been satisfied and ...

Page 9: ... 7 times The display should now show Enter Menu Code 0704 6 Press the Enter Reset button The display should now show Enter Menu Code USER CODE 3 3 MENU SET A GENERAL SETTINGS After 2 seconds the screen will show A General B N A Pressing the Enter Reset button will access the General menu set From here the following sub sections can be accessed by moving the caret symbol to the appropriate line usi...

Page 10: ...tore the desired setting 3 3 6 NIGHT SETBACK TEMPERATURE Once the internal clock has been set correctly the night setback feature can be used to program a lower water temperature set point for water heating This feature is only used when a tank sensor is used The temperature range for this parameter is 0 C to 60 c The feature is turned off with a setting of 0 C The default value is 0 C To modify t...

Page 11: ... setpoint of the water heater to be adjusted when a flow temperature sensor is not used Lochinvar Limited recommends that a flow sensor is always used with this appliance The setpoint should be adjusted to ensure that the water is stored at 60 C and distributed at 50 C within 1 one minute at all outlets Care is needed to avoid much higher temperatures because of the risk of scalding At 50 C the ri...

Page 12: ......

Reviews: