background image

Function Programming

Steps

Remark

Function

Please run the door-handing identifying process before function set up when first time installation or
default setting restore. 

It should be remained

 unlock while programming.

Up to 6 sets of User Code can be saved. User Code should be 4-10 digits in length.

Auto-locking and K eypad locking function will be invalid when User Codes are deleted.

The lock can only be operated by key during the time.

The preset delay-time is 30 seconds, you can change the time by following 
instruction. Repeat the steps to cancel the Auto-locking function.

10-99 seconds delay -time available.

Repeat same steps to turn beeper On/Off . 
LED illumination is still functioning when it's in mute. But there will be no any warning alarm.

Auto-locking and K eypad locking function will be invalid when User Codes are disabled. The lock can
only be operated by key during the time. Repeat the steps to enable the User Codes again.

Disposable code will be no longer valid once being used.

Press “R” button for over 5 seconds, the programming will complete after you hear 3 long beeps.
After restore, you need to run the door handing identifying process before other function setting.

Detect Left / Right

Hand Door Installation

Add New UC

Delete An Existing UC

Delete All UC At once

Change PC

Toggle Autolock

On/Off

Set Autolock Time

Delay

Toggle Mute On/Off

Enable/Disable All UC

Create a disposable

UC

Restore all preset lock

settings

Press “R”

Enter PC

Enter PC

Enter PC

Enter PC

Enter PC

Enter PC

Enter PC

Enter PC

Enter PC

Enter PC

Press 0

Press 1

Press 2

Press 3

Press 4

Press 5

Press 6

Press 7

Press 8

Press 9

Programming Code (PC)
User Code (UC)

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Programming

Button

Enter new UC

Enter the UC you

want to delete

Enter New PC

Enter Seconds

(10~99)

Enter

new disposable

UC

S pe c ific a tion

/

F unc tion 

¿

]

{

}

¡

«

»

USER MANUAL

Programming Button

      

Programming Button is for entering codes, clearing errors and

        setting function. It's also lock button. 

Number Buttons

        Input the pass codes, each pass code is 4-10 digits in length.

Cylinder

        Retract / Extend the latch bolt by key from exterior .

¡ 

Washer

        Prevent water permeating into lockset.

¿ 

Battery Lid

       Slide the lid to change the batteries
       or restore default setting.

« 

Battery Holder

 

    

Four AA

1.5V

Alkaline batteries.

» 

R Button (Reset)

       Restore default setting.

‹ 

Turn-Piece

       Retract/Extend the latch
       bolt from interior .

1.Battery

Four AA

1.5V

Alkaline batteries.

2.Low Battery

2-1  The batteries should be changed immediately once you see
       the LED flashes in red and hear constant beep sounds for
       about 10 seconds when press programming button. 
2-2  All settings are retained in the memory and will not be
       affected even if the battery is completely dead.
2-3  The lock still can be operated by key even there is a power
       outage.

3.LED Indicator

3-1  LED flashes green once when successful operation.
3-2  LED flashes green twice when successful programming.
3-3  LED flashes red 3 times when there is an operation error .
3-4  LED flashes red 5 times when codes input error , the operation
       will stop for system protection (Refer to 17).
3-5  LED flashes orange 3 times when system has been restored
       to default setting.
3-6  LED flashes orange slowly while in programming mode.

4.Audio Indicator

4-1  1 beep sound indicates a successful operation.
4-2  2 long beeps indicate a successful programming
4-3  3 beeps indicate an operation error .

4-4  3 long beeps indicate that system has been restored to
       default setting.
4-5  5 beeps when codes input error , the operation will stop for

        

system protection. (Refer to 17)

4-6  10 rapid beeps indicate the power of battery is low .

5.Programming Code

5-1  The preset Programming Code is 0000. Please delete it and

        

create your personal code when first time operation.

5-2  Only one set of Programming Code for function setting. 
5-3  Programming Code is only for function setting, you can't

        

unlock the door by pressing Programming Code.

5-4  Programming code is 4-10 digits in length. 
5-5  Programming code can be changed anytime if needed.

6.User Code

6-1  The preset User Code is 1234. Please delete it and create

        

your personal code when first time operation.

6-2  Up to 6 sets of User codes can be saved.
6-3  User Code is only for activating the lock, without

        

programming function.

6-4  User Code is 4-10 digits in length.
6-5  User Code can be deleted or changed anytime if needed.

7.Delete Individual User Code

7-1  User Codes can be deleted individually . You can reset the

        

same number as code even it's deleted before.

7-2  Y ou should enter Programming code to delete individual

        

User code.

8.Delete All User Codes At Once

8-1  All the User Codes can be deleted at once. Y ou can still reset
       the same numbers as codes even they're deleted before.
8-2  Auto-locking and K eypad locking function will be invalid
       after deleting all User Codes and the lock can only be
       operated by key . All the electrical functions will be restored
       when recreate new User Codes.
8-3  Y ou need to enter Programming Code to delete all User
       Codes.

9.Temporarily Disable All User Codes

9-1  Auto-locking and K eypad locking function will be invalid
       when User Codes are temporarily disabled. The lock can only
       be operated by key during the time.
9-2  Repeat the programming steps again to restore the User
       Codes.

10.Create a Disposable User Code

10-1 Disposable User Code will be no longer valid once being used.
10-2 Y ou can reset same number as Disposal User Code. 
10-3 Y ou need to enter Programming Code to create a
        Disposable User Code. 

11.Restore Preset F actory Code

11-1 Y ou can restore Preset F actory Code by pressing “R” button
        on the interior receiver module when you forget Programming
        Code or you want to cancel all previous setting.
11-2 After restore, the Programming Code would be 0000; the
        User Code would be 1234 again.

12.Unlock the door

The door will be unlocked by key or pressing User Code on
keypad from outside or by interior turn-piece.

13.Lock the door

The door will be locked by key or pressing Programming Button
on keypad from outside or by interior turn-piece.

14.Incomplete Door Closing / Opening

14-1

 

Once the latch bolt is not extended/retracted completely

         

and causing a not functional motor operation when it's

         

locked by keypad, you'll see LED flash red 3 times (for twice)

        and hear 3 beeps (No alarm when it's in mute). Y

ou need to

        enter User Code to unlock the door for remaining the bolt

         

retracted, and press Programming Button to lock the door

         

again.

14-2 If the latch bolt gets stuck or can't extend/retract

         

completely all the time, please check if the strike aligns with

         

the latch bolt perfectly and adjust the strike to proper 

         

position. After long use of the door hinge, the latch bolt

         

might get stuck easily because the door is deformed or

         

lopsided.

15.To Activate / Deactivate Auto-Locking F unction

15-1

 

The door will automatically lock itself within 10~99 seconds

         

when this function is programmed.

15-2

 

This function is not preset at the beginning; it can be set if

         

needed.

15-3

 

The preset delay-time is 30 seconds; you can adjust the

         

period you want.

15-4

 

Please repeat the same programming steps to cancel

         

Auto-Locking function when needed.

15-5

 

The system will alarm twice if

 

the latch bolt gets stuck

         

or not

 

extended/retracted completely.

         

You need to enter User Code to unlock the door for

         

remaining the bolt retracted. The auto-locking function will

         

be restored then.

16.Toggle Mute On/Off

16-1 Y ou will hear beep sounds when pressing keypad,
        programming or operating errors. It can be turned off if
        needed. 
16-2 LED Illumination is still functioning when it's in mute. F or
        there will be no any warning alarm, we suggest not to mute
        the beeper if it's not necessary .   
16-3 Motor operating sound cannot be muted.

 

17.Code Protection F unction

The operation will stop if entering unauthorized codes over 5
times. The System will re-operate again after 45 sec.

18.Illumination

The LED Keypad will light up when pressing any button for ease
of operating in the dark.

1. It should be remained unlock while programming.
2. Please run the door -handing identifying process
    (Refer to programming table) before function set up when first
    time installation or default setting restore.
3. Please change default Programming Code (0000) and User
    Code (1234) before function set up when first time operation.
4. LED flashes orange slowly while programming. LED flashes
    green twice with 2 long beeps when correct input. LED flashes
    red 3 times with 3 beeps when incorrect input.
    (Y ou need to wait for 6 seconds or press programming button
    when incorrect input, then re-program the system again.)
5. Every programming step should be done in 6 seconds.
6. You can lock/unlock this product by either key or pass code.
    Please refer to the following programming table for function
    set up.

P ass Code & F

unction Set up

Remark

1. W e recommend to use alkaline battery in order to stabilize the
    power supply .
2. Do not mix alkaline battery with regular zinc-carbon ones or
    mixed brands.
3. Do not use any chemical liquid or lubricating oil with additives
    to clean the lock body , it will damage the surface or even
    mainboard.
4. If there is any problem of the product, please contact your
    local retailer and send back the product to us for repair or
    replacement.

Lockey Digital Systems Inc.

www.lockeyusa.com

Reviews: