USING THE POWER DISTRIBUTION UNIT WITH THE REMOTE CONTROL
1. Pressing the SAFE-ON button on the Remote Control will turn ON all groups of outlets sequentially and will remain on
until any other mode is set.
2. Pressing the 1HR-ALL or 3HR-ALL buttons on the Remote Control will activate ECO-TIMER_ALL mode.
a) All groups of outlets will turn on sequentially and will turn off automatically after one or three hours has elapsed
respectively.
b) The MODE indicator will flash the number of times corresponding to the specific button pressed to reflect the
timer duration. Ie pressing the 3HR-ALL button will result in three flashes, corresponding to a 3-hour timer
duration.
3. Pressing the 1HR CYCLE or 3HR CYCLE buttons on the Remote Control will activate ECO-TIMER-CYCLE mode. This
function cycles each group of outlets on the Power Distribution Unit, giving it a set amount of charge time.
a) The time duration is determined by the specific CYCLE button pressed. Ie 1HR-CYCLE button corresponds to 1-
hour timer duration,
b) When the timer duration has elapsed the group of outlets will be turned OFF and the next consecutive group of
outlets will turn ON automatically.
c) The MODE indicator will flash the number of times corresponding to the specific CYCLE button pressed to reflect
the timer duration. Ie pressing the 3HR-CYCLE button will result in three flashes, corresponding to a 3-hour timer
duration.
4. Pressing the SAFE-OFF button on the Remote Control will put the Power Distribution Unit into SAFE-OFF mode
cancelling any other mode.
USING THE POWER DISTRIBUTION UNIT WITHOUT THE REMOTE CONTROL
Setting the operating mode without the Remote Control:
1. Pressing the MODE button consecutively will cycle the Power Distribution Unit through its different operating modes
in this sequence: SAFE-ON to ECO-TIMER-ALL to ECO-TIMER-CYCLE to SAFE-OFF and repeating from the start.
2. The MODE indicator will indicate the operating mode of Power Distribution Unit:
a) In SAFE-ON mode, the MODE indicator will be on continuously.
b) In ECO-TIMER-ALL mode, each group of outlets will turn on sequentially and the MODE indicator will flash the
number of times corresponding to the programmed timer duration. Eg Three flashes indicates a 3-hour setting.
c) In ECO-TIMER-CYCLE mode, only one group of outlets will turn on and the MODE indicator will flash the number
of times corresponding to the programmed timer duration. Eg One flash indicates a 1-hour setting.
NOTE: The outlet indicator will show the group of outlets that is ON;
o
If the group of outlets is powered OFF the outlet indicator will be OFF.
o
If the group of outlets is powered ON, the outlet indicator will be ON.
d) In SAFE-OFF mode, the MODE indicator will be OFF.
SETTING THE PROGRAMMED TIMER DURATION IN ECO-TIMER-ALL OR ECO-TIMER-CYCLE MODES:
1. When the Power Distribution Unit is in ECO-TIMER-ALL mode, pressing and holding the MODE button on the Power
Distribution Unit for 3-seconds will allow the programmed timer duration to be changed.
2. After 3-seconds have elapsed the MODE indicator will flash quickly.
3. Continuing to hold the MODE button down will cycle the programmed timer duration through this sequence, pausing
for 3-seconds between each duration option;
o
1-hour (outlet indicator for Group-1, Outlet #1 and #2, will illuminate),
o
2-hours (outlet indicator for Group-2, Outlet #3, will illuminate),
o
3-hours (outlet indicator for Group-3, Outlet #4, will illuminate),
o
4-hours (outlet indicator for Group-4, Outlet #5, will illuminate), and repeat from the start.
4. Release the MODE button on the desired Time setting. Eg If you want the ECO-TIMER-ALL to charge for 2 hours,
release the MODE button when outlet indicator for Group-2 is illuminated.
5. The MODE indicator will flash the number of times corresponding to the number of hours programmed. Eg Two
flashes indicate a two hour setting.
6. The programmed timer duration will survive any loss of power.
SAFETY INSTRUCTIONS
For your safety - Discard the Power Distribution Unit if the enclosure is damaged.
To reduce the risk of fire, electrical shock and/or injury, the following basic precautions should be followed:
Summary of Contents for Carrier 30 Cart
Page 8: ...www pclocs com au www lockncharge com...
Page 16: ...www pclocs com au www lockncharge com...
Page 24: ...www pclocs com au www lockncharge com...
Page 32: ...www pclocs com au www lockncharge com...
Page 40: ...www pclocs com au www lockncharge com...
Page 48: ...www pclocs com au www lockncharge com...