GM10
by
www.accureader.com
info@locktech.biz
Thank you for purchasing the AccuReader
wafer reading system by LockTech. This system will
allow you to read the door/trunk wafers in GM10 cut
vehicles. Following a few simple steps it takes only
minutes to read the depths for each cut in each. The
GM10 AccuReader is not designed to be used on the
newer GM10 cut key commonly referred to as a Z
key.
The GM10 AccuReader comes with 2 keys.
One is designed to read any wafers in positions 1-5
and the other key is designed to read any wafers
found in positions 6-10. Using both keys allows for
reading the more shallow wafer positions with a fully
or almost fully inserted key, increasing the accuracy.
The AccuReader works on the process of
elimination to decipher the correct depths of the lock.
By checking the deepest cut first you eliminate what
the cuts are not. Therefore it is essential to always
read depth slide #4 first.
Please take the time to familiarize yourself
with the tools and verify all pieces are accounted for
from the list of contents below:
Package Contents:
2-AccuReader keys
1-insertion/release slide
1-GM10 depth slide #4
1-GM10 depth slide #3
1-GM10 depth slide #2
1-Tube storage container
1-Tube Cap
USING THE ACCU-READER
1) Always thoroughly clean the lock with a electronics
safe cleaner to free any potentially stuck wafers.
Cycle a key blank in and out of the lock approx. 20
times.
2) Use the alignment holes in the AccuReader key to
assist in judging the distance from one wafer position
to the next. Wafer orientation will vary depending on
the vehicle. It is recommended to use a resource
such as AutoSmart to determine wafer locations for
specific models.
3) Place the insertion/release slide in the slot on the
AccuReader key for the 6-10 spaces. Fully insert the
AccuReader key into the keyway and remove the
slide. Pull the AccuReader outward until a wafer
traps and note the alignment holes. Removing the
AccuReader flipping it over and repeating this step
will determine if the deepest wafer is on the top or
bottom. After this has been determined, Reinsert the
AccuReader and trap the deepest wafer.
WHEN
YOU TRAP A WAFER JIGGLE THE ACCUREADER
KEY TO INSURE THE WAFER HAS DROPPED
COMPLETELY TO ITS NORMAL RESTING
POSITION BEFORE READING.
4) Always
start reading with the #4 depth slide
tool, then proceed to #3, then #2 “if necessary.”
Fully insert the depth slide into the AccuReader key.
The alignment mark on the depth slide will line up
with the (
Y
)
Yes
mark or it will line up with the (
N
)
No
mark.
a) If the #4 depth slide lines up with the
Y
then the depth for that wafer is a 4. If the depth slide
lines up with a
N
, then you must proceed to the #3
depth slide.
b) If the #3 depth slide lines up with the
Y
then the depth for that wafer is a 3. If the depth slide
lines up with a
N
, then you must proceed to the #2
depth slide.
c) If the #2 depth slide lines up with the
Y
then the depth for that wafer is a 2. If the depth slide
lines up with a
N
, then the depth for that wafer is a 1.
d) Repeat steps a) through c) for each wafer
position until you have recorded the depths for all
wafers in positions 6-10.
e) Using the GM10 AccuReader key for 1-5
spaces repeat a), b), & c) above to read any wafers
found in positions 1-5.
Remember when the GM10
AccuReader key for 1-5 is fully inserted into the
keyway the wafer trap is aligned with position 5.
Starting with position 5 continue to read all the
remaining wafers.
g) You now have recorded all the positions to
make a working key for that lock. Progression can be
used to finish the ignition cuts for a complete key.