SET UP AND OPERATING INSTRUCTIONS
1. Snap two stands into holes located on front of dispenser housing. Move front stand
forward to “rest” position and stand dispenser on flat work surface. Large wire platform
stand slides into dispenser base.
2. Unwrap power cord and insert cord into handle of dispenser. Plug cord into standard
electrical outlet. Amber indicator light will be illuminated when dispenser is connected to
power source. Operates on standard 120V, 50/60Hz, AC only outlet.
3. Insert high-temperature glue stick into dispenser and allow 3-5 minutes for dispenser
and stick to heat up.
4. After dispenser and stick are heated, move wire stand to “rear” position. Apply glue to
work pieces with continuous squeezing pressure on trigger. Amount of glue released onto
work piece is determined by amount of pressure applied to trigger. Release trigger to stop
glue flow.
5. Apply even pressure to work pieces for complete bonding.
6. Do not attempt to remove unused glue from the dispenser after use. Any unused portion
of the glue stick can remain in the dispenser and be re-heated for use later.
SPARE PARTS
Item Number Description
916050 050A .090” diameter Nozzle/Check Valve
REPLACING THE NOZZLE
Only replace the nozzle while the tool is still warm. Disconnect the tool from the power
supply before proceeding, and always use protective gloves.
PREVENTIVE MAINTENANCE
When in use, do not lay the tool on its side. Always use the stands provided.
Do not use excessive force on the trigger.
Ensure that the tool has fully warmed up
before using.
If the tool is going to be left idle for 30 minutes or more, the tool should be unplugged.
Inspect and clean the nozzle on a daily basis.