5.1.1 Tube Guide adjustment
If a large diameter feedline is used and the Pump head 12 does
not rotate then follow the procedure below:
1.
Lift Guide Lock 1.
2.
Unscrew the bigger lock grip from the smaller one.
3.
Turn the screw counterclockwise one revolution.
4.
Assemble both lock parts.
5.
Close the Tube Guides 1 as described in Section 5.1 and start dispensing.
5.1.2 Best practice guidelines
•
Keep the product feedlines as short as possible. Typically, the product feedline should not
be longer than 2 m.
•
Avoid kinking of the feedlines
•
Ensure all fittings are secure and tight
5.2 Mounting the Feedline to the Applicator
1.
Pull the tube through the applicator and the applicator tip adapter.
2.
Mount the applicator tip adapter.
3.
Screw on the tip adapter
4.
Cut the feed tube as right picture.
5.
Install the required dispensing needle
5.3 Mounting the Feedline to the Product Bottle
Dispensing Cyanoacrylate:
⚫
Cut the nozzle of the bottle only as much as it is necessary to insert the tube.
Notice!
It is necessary to minimize moisture access to the bottle that causes curing of the CA.
Dispensing Anaerobic:
⚫
Unscrew the dispensing cap.
Summary of Contents for 2265279
Page 5: ...Operating Manual Page 5 2 Description 2 1Overview ...
Page 8: ...Operating Manual Page 8 ...
Page 10: ...Operating Manual Page 10 Manual Applicator Finger Switch ...
Page 11: ...Operating Manual Page 11 Caution Switch off the unit before connecting the finger switch ...
Page 18: ...Operating Manual Page 18 7 Diagrams XS1 START Interface ...
Page 20: ...Operating Manual Page 20 9 Declaration of Conformity ...
Page 21: ...Operating Manual Page 21 ...