Operating Manual
- Page 15 -
5.4.1
Program
Dispenser running data can be saved in a defined program.
When start to edit running data, operator need to defined a program number.
1.
Press MODE Button 9, switch to PROGRAM. (PROGRAM indictor on)
2.
Press SET, edit program number. 00~29 are available.
3.
Press MODE to confirm.
5.4.2
Manual Mode
1.
Press MODE Button 9, switch to MANUAL mode. (MANUAL indictor on)
2.
Setup CW/CCW via CW/CCW button 8.
3.
Setup dispensing speed via speed adjustment button 5.
4.
Run dispenser via press SHOT button, Finger Switch on applicator 17 or footswitch.
5.4.3
Time Mode
In Time Mode, operator defines dispensing time then dispenser will run one cycle per initiation.
1.
Press MODE Button 9, switch to TIME mode. (TIME indictor on)
2.
Setup dispensing speed via speed adjustment button 5.
3.
Setup dispensing time as below:
1)
Press SET button for 2 seconds, then edit dispensing time.
2)
Press MODE 9 to confirm.
or
1)
Press TEACH 6, TEACH indicator will flash.
2)
Press SHOT button, Finger Switch on applicator 17 or footswitch until desired quantity is
achieved.
3)
Press TEACH 6, or MODE 9 to teach in dispensing time.
4.
Run dispenser via press SHOT button, Finger Switch on applicator 17 or footswitch.
Summary of Contents for 2265279
Page 5: ...Operating Manual Page 5 2 Description 2 1Overview ...
Page 8: ...Operating Manual Page 8 ...
Page 10: ...Operating Manual Page 10 Manual Applicator Finger Switch ...
Page 11: ...Operating Manual Page 11 Caution Switch off the unit before connecting the finger switch ...
Page 18: ...Operating Manual Page 18 7 Diagrams XS1 START Interface ...
Page 20: ...Operating Manual Page 20 9 Declaration of Conformity ...
Page 21: ...Operating Manual Page 21 ...