Operating Manual
- Page 16 -
5.4.4
Cycle Mode
In CYCLE mode, you will need to setup interval time which is the delay between the end of
dispense and the Vacuum suck back. .
To setup interval time:
1.
Press MODE Button 9, switch to CYCLE mode. (TIME indictor on)
2.
Setup Interval time as below:
1)
Press SET button for 2 seconds, then set interval time.
2)
Press MODE 9 to confirm.
Or
1)
Press TEACH 6, TEACH indicator will flash.
2)
press SHOT button, Finger Switch on applicator 17 or footswitch until get desired interval
time.
3)
Press TEACH 6, or MODE 9 to teach in interval time.
3.
Run dispenser via press SHOT button, Finger Switch on applicator 17 or footswitch. Press
again, cycling will be stopped.
5.4.5
Vacuum Mode
Vacuum will work with TIME and Cycle. Operator will need to setup vacuum time. Dispenser will
run as TIME
→
INTERVAL Time
→
Vacuum Time. Dispenser runs one cycle per trigger.
1.
Press MODE Button 9, switch to VACUUM mode. (TIME indictor on)
2.
Setup dispensing time as below:
1)
Press SET button for 2 seconds, then set vacuum time.
2)
Press MODE 9 to confirm.
Or
1)
Press TEACH 6, TEACH indicator will flash.
2)
press SHOT button, Finger Switch on applicator 17 or footswitch until get desired vacuum
time.
3)
Press TEACH 6, or MODE 9 to teach in vacuum time.
3.
Run dispenser via press SHOT button, Finger Switch on applicator 17 or footswitch.
5.4.6
Continue Mode
Summary of Contents for 2265279
Page 5: ...Operating Manual Page 5 2 Description 2 1Overview ...
Page 8: ...Operating Manual Page 8 ...
Page 10: ...Operating Manual Page 10 Manual Applicator Finger Switch ...
Page 11: ...Operating Manual Page 11 Caution Switch off the unit before connecting the finger switch ...
Page 18: ...Operating Manual Page 18 7 Diagrams XS1 START Interface ...
Page 20: ...Operating Manual Page 20 9 Declaration of Conformity ...
Page 21: ...Operating Manual Page 21 ...