12
3
2
1
AIR INLET
AIR MANIFOLD
PRESSURE REGULATOR
NEEDLE VALVE
AIR OUTLET
SOLENOID VALVE
Needle Kits and Air Line Adapters – check
Disposable
Dispense Components
listing at
www.equipment.loctite.com
9
I/O Configuration & Pneumatic Diagram
Upon completion of a dispense cycle, an open collector circuit
closes and remains closed until the next dispense cycle. This
circuit can be used to signal back to a host computer, start
another device in sequence, or drive any other operations that
need to be tied to the completion of the dispense cycle. Upon
closure, (end of dispense cycle), power from an external source
is allowed to pass through the circuit to operate a 5 to 24 VDC
load. Power consumption must not exceed 250 mA. The load
could be a relay, solenoid, counter, LED, or any device that will
operate within a 5 to 24 VDC range and a maximum of 250 mA.
To initiate a dispense cycle
During cycle = GROUND
End of cycle = OPEN
During cycle = GROUND
End of cycle = OPEN
To initiate a dispense cycle
with contact closure
Chasis Ground
Pin 7, 8 and 9 = available
PIN 1
PIN 2
PIN 3
PIN 5
PIN 6
PIN 5
PIN 4
Pneumatic Diagram