2 Description
7 Vacuum Control
Control for pulling a vacuum in the syringe.
With this vacuum, the product is sucked back during dispensing pauses to prevent
dripping.
– Turning in the counter clockwise direction: The vacuum action is increased until
the dripping stops.
– Turning in the clockwise direction: The vacuum action is reduced.
8 Pneumatic Connection for Syringes (Outlet)
9 Precision Pressure Regulator
Precision regulator for adjusting the dispensing pressure.
By turning the regulator knob, the dispensing pressure is adjusted in the range
from 0.00 to 7.00 bar (0.00 to 100 PSI).
If the error message
Press. 0.83 NOK
“ appears with beeping, the dispensing
pressure was changed more than ± 10 %. The value
0.83
[bar/psi] is only an
example for the displayed dispensing pressure (see Chapter 7).
By pressing button, the indicated dispensing pressure is stored as the new
comparison value for automatic pressure monitoring. The error message and
beeping is eliminated.
10 Power Switch I/O (ON/OFF)
11 Hose Clamp
12 Syringe Airline Adapter Assembly
13 End Cap Adapter
14 Plug
Makes possible the clean emptying of the Syringe
15
and prevents the permeating
of the product with air as well as the product running back out of the Syringe
15
into the control unit.
15 Syringe
Store filled syringes only with Luer-Lock tip caps
17
and end caps
13
.
16 Dispensing needle
17 Luer-Lock Tip Cap
18 Pencil Holder
19 Power Cord
20 Footswitch
Functions is the same manner as button
4
START
21 Pneumatic Connection P in
22 Exhaust Air Silencer
When necessary, can be replaced with a micro-filter or a hose connection to collect
the exhaust air.
23 Power Fuse
Warning!
Removing, bypass or putting out of operation of the safety devices can result in damage
to the unit and is therefore prohibited!
24 Power Supply Socket
25 Socket XS1: Start
The Footswitch 20 is connected here.