Dispensing
5
32
5.1
First Operation
Before loosening the cover screw fasteners 2,
the reservoir must be depressurized
(pressure-free)!
Reservoir 97105 or 97107:
●
Set the depressurizing valve
5
to position
(depressurize).
☞
Automatic reservoir only:
The automatic reservoir is depressurized when the power switch on the controller 97102 or 97103 is
switched to the
O
(OFF) position or the digital display indicates no pressure.
In case of doubt:
●
Set the depressurizing valve
5
to position
(depressurize).
5.1.1
Inserting the Product Bottle
●
Loosen the cover screw fasteners
2
and remove the cover
1
.
●
Check that the dispensing valve is connected correctly according to the instruction manual.
Never fill the product directly into the reservoir!
The safety devices would become clogged and therefore ineffective!
●
Insert a full product bottle in the reservoir
☞
Automatic reservoir only:
●
Check that the product bottle inserted in the bottle nesting block is pressed against the level sensor
(see Section 4.3).
●
Insert the product hose into the bottle and put
on the cover
1
.
●
Uniformly tighten the cover screw fasteners
2
.
●
Set the depressurizing valve
5
to position
(pressurize).
●
On the controller 97102, switch the reservoir to active with the button
.
On the controller 97103, switch the reservoir to active with button
or
.
B
A
R