36
Type of malfunction
Possible causes
Correction
No product.
– Product reservoir is empty.
The red LED on the automatic reservoir
is lit.
– Product reservoir is not switched on.
– Reservoir (product reservoir) is not active.
– Product reservoir defect.
●
Refill the product reservoir
(Section 5.2)
On the automatic reservoir, one of the
seven yellow LED´s was previously lit.
The lower the lit LED, the lower the filled
level.
●
Set the depressurizing valve to
(pressurize).
●
Controller 97102: Press button
.
Controller 97103: Press button
or
.
●
Loctite Service.
B
A
Troubleshooting
7
Replacing the Rupture Disc
☞
When the maximum allowable air supply pressure is exceeded, the reservoir is depressurized by the
bursting of the rupture disc. he punctured rupture disc must be replaces.
●
Loosen the cover screw fasteners
2
and remove
the cover
1
.
●
Remove the screws and open the housing.
●
Remove the rupture disc screw.
●
Replace the punctured rupture disc with a new
one.
Replace and tighten the rupture disc screw.
Tightening torque: maximum 20 Nm
Affix the sypplied type plate.
●
Close the housing. Insert and tighten the screws.
XS2/IN: Controller
XS2/OUT:Tank B
max. operating pressure
8 bar
operating temperature.
0 to +50C
volume:
3,5 Liter