8.5
Needle Calibration
The program below shows how to use the needle calibration features.
Robot will perform needle calibration before dispensing. And will repeat if the needle calibration
counter numbers has been reached. .
Addr. Command
Notes
0001
Needle Adjustment
Robot performing needle calibration before
dispensing start.
0002
Needle Adjustment counter (5)
Perform needle calibration every 5 cycles.
0003
Line Speed ( 50 mm/s )
Sets the line speed to 50 mm/sec.
0004
Line Start (10, 10, 35)
Registers a Line Start point at
X: 10 mm, Y: 10 mm, Z: 35 mm
0005
Line Passing (10, 20, 35)
Registers a Line Passing point at
X: 10 mm, Y: 20 mm, Z: 35 mm
0006
Line End (10, 40, 35)
Registers a Line End point at
X: 10 mm, Y: 40 mm, Z: 35 mm
0007 End
Program
Ends the program. Returns the tip to the
home position.
Summary of Contents for EQ RB20 500D
Page 5: ...Operating Manual Page 5 SECTION 1 Introduction ...
Page 8: ...Operating Manual Page 8 SECTION 2 Setup ...
Page 10: ...Operating Manual Page 10 SECTION 3 Tour of Robot ...
Page 12: ...Operating Manual Page 12 SECTION 4 Tour of Teach Pendant ...
Page 21: ...Operating Manual Page 21 SECTION 5 MENU Introduction ...
Page 30: ...Operating Manual Page 30 SECTION 6 Programming ...
Page 39: ...Operating Manual Page 39 SECTION 7 Function Reference ...
Page 98: ...Operating Manual Page 98 SECTION 8 Sample Programs ...
Page 107: ...Operating Manual Page 107 SECTION 9 Software Upgrade ...
Page 109: ...Operating Manual Page 109 SECTION 10 Error Messages and Specifications ...
Page 119: ...Operating Manual Page 119 SECTION 11 Maintenance Accessories Spare Parts ...
Page 124: ...Operating Manual Page 124 SECTION 12 Equipment Warranty ...