Products and functions
YarnMaster PRISMA
www.loepfe.com
17
Trend
Graph representation of the trend curve over a period of 72 hours
5 different settings can be defined for group or spindle
3.3.2
LabPack (Option)
SFI/D clearing
SFI/D short
Intensity
Threshold value for fault
length
±5 – ±100 %
1 – 10 m
SFI/D long
Intensity
Threshold value for fault
length
±5 – ±100 %
10 – 50 m
Imperfections (IPI)
Count of the most frequent yarn faults by diameter threshold value per 1000 m
Neps
Diameter threshold value
>1.80
Thick
Diameter threshold value
>1.30 – (<1.80)
Thin
Diameter threshold value
<0.8
Count of the most frequent yarn faults by diameter threshold value per m
Small
Positive deviation
diameter threshold value
1.20 – 1.30
Negative deviation
diameter threshold value
0.83 – 0.8
Count of the most frequent yarn faults by length threshold values per 1000 m
4 yarn fault classes in the range of
2 – 70 cm
Positive and negative deviation with di-
ameter threshold values
>1.30 or < 0.80
IPI alarm
Monitoring of IPI diameter and IPI length
8 different “alarm” settings can be defined for group or spindle