Startup
24
www.loepfe.com
YarnMaster PRISMA
Label
Type
Description
Power
D-sub PSC
Power supply 24 V DC
Contact 1: (+) 24 V DC
Contact 2: not connected
Contact 3: (-) 0 V DC
This connection must only be supplied with 24
V DC.
Screw connection
Protective grounding
This separate ground pin must be connected
to protective grounding!
Clearer
D-sub 9-pole connector
Connection to Loepfe 2-wire bus (L2B)
HDMI
HDMI
HDMI port, recommended resolution 1366 x 768
DP
Display Port, recommended resolution 1366 x 768
LAN 1
RJ45
Network connection, static IP 192.168.1.200
Caution: Accidental modification of the LAN 1 IP address
may break the connection with the Savio control unit!
LAN 2
RJ45
Network connection, dynamic IP DHCP
/
USB 3.0
USB port (4x)
4.6
Installing the sensing head
WARNING
Working on running machines poses a risk of severe physical
injury.
4
Switch off machines and wait until they have come to a complete stop.
4
Work on electrical components may only be performed when the system is
switched off and disconnected from power.
4
Before installing or performing maintenance on machines, disconnect the
compressed air supply and release the pressure from the machines’
compressed air system.
4
Before operating, ensure that all appropriate covers are in place.
NOTE
Before installation, ensure that the machines are equipped with an overpressure
release mechanism.
Sensing heads may only be installed on machines with overpressure release
mechanisms.